The 16th AIVC Conference - Implementing the results of ventilation research, was held in Palm Springs, USA, 18-22 September 1995.

Contains 51 papers.

Volume content

Enter a comma separated list of user names.
The Building Research Establishment is currently investigating the impact of various radon remedies at a radon affected test house. Tests aim to assess how different ventilation strategies affect indoor radon levels and the building environment.
Welsh P A
Two factors - CO2 emissions fiom heating and cooling systems and restrictions on the use of CFC refrigerants - have accelerated the development and introduction of new and more environmentally friendly cooling systems.
Dehli F
In line maintenance hangars, air planes stay about 2 hours, usually at night-time.
van der Maas J, Schaelin A
The installation of packaged heat recovery ventilation (HRV) systems has recently become common practise in new homes in Canada.
Hill D
This paper presents the results of a series of measurements made in an occupied family house. Long and short-term measurements of the concentration of radon gas in the cellar and other living areas of the house were carried out.
Wang F, Ward I C
This paper describes the new indoor environment research facility recently constructed at the Institute for Research in Construction, National Research Council Canada.
Shaw C Y, Barakat S A, Newsham G R, Veitch J A, Bradley J
Airtightness and infiltration rate measurements in office and other commercial buildings have shown that these buildings can experience significant levels of air leakage [1,2]. The energy impact of air leakage in U.S.
VanBronkhorst D, Persily A K, Emmerich S J
The work concentrated on estimating the effects of building leakages and terrain parameters on the air infiltration.
Sateri J, Heikkinen J, Pallari M-L
So as to better understand and predict IAQ problems, the velocity field and distribution of local mean age of air were determined experimentally with three-dimensional anemometry and decaymode tracer gas measurements inside a classroom.
Regard M, Carrie F R, Voeltzel A, Richalet V
A high resolution particle-imaging velocimetry has been developed and applied to study full-scale room air flows.
Cui M M, Topp C, Pedersen S, Christianson L L, Adrian R J, Leovic K W
Three different examples illustrate the possibilities offered by the use of tracer gas methods for detailed airborne moisture transport studies in building.
Ducarme D, Bossaer A, Wouters P
The material presented in this paper highlights some aspects of""two research projects, The control of natural ventilation , and Night cooling strategies . The research has led to the development of generic control strategies.
Martin A
The IEA Annex 27, "Evaluation and Demonstration of Domestic Ventilation Systems" is aiming at developing tools by using the most developed computer models and equations available including modul development.
Mansson L-G
A preliminary study of the potential for using central forced-air heating and cooling system modifications to control indoor air quality (IAQ) in residential buildings was performed.
Emmerich S J, Persily A K
The use of IR detectors to steer the ventilation is in principle an attractive approach for optimising the ventilation according to the occupants needs.
Ducarme D, Wouters P, L Heureux D
Thirty-one independent fan pressurization measurement series were performed on seven apartments in three family housing buildings at Fort Riley, Kansas, using four protocols.
Flanders S
Especially in modern buildings with small capacity of humidity storage it is necessary to reduce the humidity in the supply air. Normally a refrigeration system containing CFC s is used.
Roeben J, Kourouma S Y
To achieve acceptable indoor air quality (IAQ), ASHRAE Standard 62-1989 recommends the use of the alternative IAQ procedure.
Meckler M
There is an increasing concern at the possible health effects of fine suspended particulate (aerosol) upon human health, particularly in the urban environment.
Byrne M A, Goddard A J H, Lockwood F C, Nasrullah M
A demand controlled ventilation system with humidity as the control parameter was tested in an experimental demonstration project in 16 apartments.
Nielsen J B, Ambrose I

Pages