Designing a model-scale experiment to evaluate the impact of steady wind on building air leakage measurements

Since the 1970s, many authors have discussed the impact of poor airtightness on building energy use, indoor air quality, building damage, or noise transmission. Nowadays, because poor airtightness affects significantly the energy performance of buildings, and even more significantly with low-energy targets, many countries include requirements for building airtightness in their national regulations or energy-efficiency programs. Building pressurization tests are increasingly used for compliance checks to energy performance requirements and may result in severe penalties.

CFD modelling of fan pressurization method in buildings – The impact of dynamic wind on airtightness tests

Building airtightness tests have become very common in several countries, either to comply with minimum requirements of regulations or programs, or to justify input values in calculation methods. This raises increasing concerns for the reliability of those tests. Despite the extensive debates about how the building pressurization test standard ISO 9972 should address sources of uncertainties, no change has been implemented. According to the current standard, the zero-flow pressure shall not exceed 5 Pa for the test to be valid.

Assessment of long-term and mid-term building airtightness durability: field study of 61 French low energy single-family dwellings

The French ongoing research project “Durabilit'air” (2016-2019) aims at improving our knowledge on the variation of buildings airtightness through onsite measurement and accelerated ageing in laboratory controlled conditions. This paper presents the final results of the second task of the project. This task deals with the quantification and qualification of the durability of building airtightness of single detached houses. It is done through field measurement at mid-term (MT) and long-term (LT) scales.  

Assessment of the durability of airtightness products in laboratory controlled conditions: development and presentation of the experimental protocol.

The airtightness of new buildings has significantly improved in the last two decades thanks to building energy performance regulations. However, until now, low knowledge is available about the evolution of buildings’ envelope airtightness. This work deals with the durability of buildings airtightness, and focuses on ways to better characterize it.

Moisture impact on dimensional changes and air leakage in wooden buildings

Wood is a hygroscopic material, it has the ability to adsorb or desorb water in response to the ambient relative humidity. Thus, the ambient air will affect the moisture content of the wood, and in turn, the dimension of the wood. If the wood itself is part of the air barrier in a construction, the shrinking and expansion can create gaps in the construction, for example in the window sill. In case of an air barrier consisting of a foil, the joints in the foil can be clamped by wooden joists, or the foil can be taped to wooden part.

Techniques to Estimate Commercial Building Infiltration Rates

The estimation of low-rise, residential building infiltration rates using envelope airtightness values from whole building fan pressurization tests has been the subject of much interest and research for several decades, constituting a major topic of discussion during the early years of the AIVC. A number of empirical and model-based methods were developed, with their predictive accuracy evaluated in field studies around the world.

Reliability of ductwork airtightness measurement: impact of pressure drop and leakage repartition on the test result

Building airtightness requirements are becoming more and more common in Europe (Leprince, Carrié, & Kapsalaki, 2017). However, airtight buildings require an efficient ventilation system to ensure good indoor air quality. In France, the inspection of ventilation system (Jobert, 2012) has revealed many noncompliance. They are mainly due to bad conception, poor implementation, and lack of maintenance. This often leads to reduced ventilation flowrates and poor indoor air quality. Leaky ductwork is one of the reasons for this noncompliance.

Influence of multizone airleakage on IAQ performance in residential buildings

This article proposes to study the impact of envelope and internal partition walls airleakage distributions, on the indoor air quality (IAQ) performance. It is based on a preliminary performance-based approach using formaldehyde with three emission levels (low, medium, high). This multizone modelling (CONTAM) approach uses as performance indicators, the average concentration per room as well as the percentage of time of exceeding the limit value (ELV) of 9 µg.m-3.

Experimental study on the measurement of Building Infiltration and Air Leakage rates (at 4 and 50 Pa) by means of Tracer Gas methods, Blower Door and the novel Pulse technique in a Detached UK Home

Air infiltration contributes to a heat loss typically representing up to one third of the heating demand of a building. The building airtightness, also quantified as air leakage, is the fundamental building property that impacts infiltration. The steady (de)pressurization method (blower door) is the widely accepted standard process for measuring building air leakage. However, this method requires the enclosure to be pressurised to a typical range of 10-60 Pa, which is not physically representative of the pressures experienced by buildings under natural conditions.

Comparison of experimental methodologies to estimate the air infiltration rate in a residential case study for calibration purposes

The air renovation of a building should be controlled in order to ensure a proper level of indoor air quality while minimize heat losses. It is a crucial point for the future energy efficiency goals. However, air infiltration rate in buildings is a complex parameter which is influenced by several boundary conditions. Although a detailed dynamic analysis could be used to properly characterize the phenomenon, estimated values can be obtained from experimental methods, as Blower Door test and gas concentration-based approaches.