Ventilated solar roof air flow and heat transfer investigation.

The governing parameters for flows generated by heat transfer from solar cell modules to air gaps are discussed. Experimental results are presented from measurements in mock-ups of ventilated facades and roofs. The heat transmitted from the solar cells to the air have been mimicked by the use of heating foils. The inclination angle of the roof, position of solar cell module and the height to width ratio (aspect ratio) have been varied. The bulk properties as the air flow rate in the air gap, local temperatures and velocities have been measured.

Beyond the intelligent facade.

           

Integrated solar thermal upgrading of multi-storey housing blocks in Glasgow.

This paper will describe a proposal to upgrade a thermally sub-standard multi-storey housing block (Type T84), where height and climatic exposure are significant, to demonstrate the effectiveness of passive, active and hybrid solar techniques to minimise space and water heating loads while enhancing the quality of air in both shared and private spaces.

Solar so good.

The Doxford Solar Office is claimed to be the first in Europe with an integrated photovoltaic facade and an holistic energy strategy. How has the building performed since completion?