The 14th International Buildair Symposium, themed "Airtight Buildings, Thermography, and Practical Ventilation Systems," is scheduled for May 16-17, 2025, in Hanover, Germany.
The event will offer a unique opportunity to find out about the latest developments and best practices, to highlight particular challenges in airtightness testing and to exchange experiences across national borders.
The Call for Papers is now open, with submissions due by September 20, 2024.
Submitted by Maria.Kapsalaki on Tue, 08/20/2024 - 15:53
The 14th International Buildair Symposium: "Airtight Buildings, Thermography and Ventilation Systems in Practice" will take place on May 16 and 17, 2025 in Hanover, Germany.
The event will offer a unique opportunity to find out about the latest developments and best practices, to highlight particular challenges in airtightness testing and to exchange experiences across national borders.
Submitted by Maria.Kapsalaki on Fri, 06/23/2023 - 13:09
The book of proceedings of the 13th International BUILDAIR Symposium "Airtight Buildings, Thermography and Ventilation Systems in Practice", held on June 2-3 2023 in Hannover, Germany. Contains 36 abstracts.
Submitted by Maria.Kapsalaki on Fri, 06/23/2023 - 12:57
Worldwide, the demand for airtightness tests of tall buildings with a height of approximately 100 m is increasing. This report provides information on the planning and measurement concept for testing the entire building as a “single-zone” and presents the results and findings of the airtightness tests. The test set-up and the tests as such are based on the Passive House Institute's Guide to Measuring Tall Buildings [5] which includes recommendations that go beyond the ISO 9972 standard.
Submitted by Maria.Kapsalaki on Fri, 06/23/2023 - 12:55
Weltweit steigt die Nachfrage nach Luftdichtheitsprüfungen von hohen Gebäuden mit einer Höhe ab ca. 100 m. Dieser Bericht informiert über das Planungs- und Messkonzept zur Prüfung des gesamten Gebäudes als „Single-Zone“ und stellt die Ergebnisse und Erkenntnisse der Luftdichtheitsprüfungen vor. Der Prüfaufbau und die Prüfungen als solche basieren auf dem Leitfaden des Passivhaus Instituts zur Vermessung von Hochhäusern [5], der Empfehlungen enthält, die über die Norm ISO 9972 hinausgehen.
Submitted by Maria.Kapsalaki on Fri, 06/23/2023 - 12:50
Purpose of the work
According to the two Swiss building standards Minergie-P and Minergie-A, individual dwelling units are considered measuring zones for airtightness, irrespective of whether they are in a new, renovated or modernized building. The Minergie standards focus on comfort between the dwelling units and the energy losses caused by infiltration.
Do zone measurements meet relevant requirements? Which requirements do the zone measurements fail to meet?
Submitted by Maria.Kapsalaki on Fri, 06/23/2023 - 12:48
Ziel der Arbeit/Fragestellung
Für die beiden schweizerischen Energiestandards Minergie-P und Minergie-A werden bei der Luftdichtheit die einzelnen Nutzeinheiten als Messzonen betrachtet, egal ob Neubau oder Erneuerung / Modernisierung. Im Vordergrund steht der Komfort zwischen den Nutzungseinheiten nebst den energetischen Verlusten durch Infiltration.
Werden bei Zonenmessungen die Anforderungen eingehalten? Welcher Anteil erfüllt die Anforderungen nicht?
Submitted by Maria.Kapsalaki on Fri, 06/23/2023 - 12:43
Purpose of the work
When dealing with very airtight buildings and buildings with flexible airtight roofing felts it might take several minutes for the differential pressure and air flow to level out after having changed the fan speed. Taking premature readings of the values causes measuring errors. The lecture provides pointers for test teams to avoid such measuring errors.
Submitted by Maria.Kapsalaki on Fri, 06/23/2023 - 12:41
Ziel der Arbeit/Fragestellung
Bei sehr dichten Gebäuden und bei Gebäuden mit flexiblen Luftdichtheitsschichten kann es nach dem Verstellen des Ventilators Minuten dauern, bis sich der Differenzdruck und der Volumenstrom praktisch nicht mehr ändern. Zu frühzeitiges Ablesen der Werte führt zu Messfehlern. Der Vortrag gibt Handlungsempfehlungen für Messteams, durch die derartige Messfehler vermieden werden.
Submitted by Maria.Kapsalaki on Fri, 06/23/2023 - 12:35
I would like to report on lessons learned in the field regarding two measurements at a special, particularly airtight and unusual building: A "concrete shell for CO2 storage in recycled concrete aggregates".