A comparison of an automated continuous formaldehyde analyser with passive dosimeters

A microprocessor-controlled, five point, all-teflon sequential air sampling system interfaced to a continuous formaldehyde analyser, the CEA model TGM 555 Air Monitor which uses the pararosaniline colorimetric method was used tomeasure the seaso

The air infiltration and ventilation rates in two large commercial buildings.

Presents data on the air infiltration and ventilation rates in 2 large commercial buildings. One building is a 4 storey, 10000m2 office building near Glasgow, Scotland; the other is a 26 storey, 100,000m2 skyscraper in Newark NJ. Collects the data on air infiltration and ventilation rates by a micro-computer based automated air infiltration system which controls the injection of a tracer gas into the various zones of the building and monitors its decay.

Continuous measurements of air infiltration in occupied dwellings.

Reports on a measurement system developed by the Institute of Technology at Tastrup Denmark, involving a microcomputer- controlled system for registering air change rates using tracer gas (nitrous oxide) according to the constant concentration method. The system is designed for measuring and metering tracer gas in up to 10 separate rooms (using an infrared gas absorption detector). It operates through automatic data logging on a floppy disc and can run without supervision for extended periods (up to six days).

Automated air infiltration measurements in large buildings.

An automated air infiltration measurement system for large buildings isdescribed. The system consists of a micro-computer, electron capture gaschromatograph, a ten port sampling manifold, and five tracer gas injectionunits. The system controls the injection and sampling of tracer gas in amulti-zone building, calculates the air infiltration rates of each zone, andmeasures the on-time of events such as HVAC fan operation, exhaust fan operation,and door/window openings.

Automatic measurements of air change rates (decay method) in a small residential building without any forced air-heating system.

Describes an automatic measurement system for air infiltration and discusses factors influencing the measurements in single rooms or in a group of connected rooms. The system works on the decay rate method and is controlled by a purpose-designed controller. The test data are evaluated off-line by computer. Discusses in detail the instrumentation and test procedure Gives results of measurements made in a detached house and correlations of the test data with wind and temperature difference data. Gives a comparison with pressurization data.

A prototype semi-automated system for measuring air infiltration in buildings using sulphur hexafluoride as a tracer.

Describes a system which automatically operates a small gas chromatograph and measures parts per billion concentrations of sulphur hexafluoride in air. It samples air on a 10-minute cycle and records the response on a strip chart recorder. When SF6 in distributed in the air of a building, data is obtained from which air infiltration rates may be determined.

Ventilation of dwellings and its disturbances

Treats importance of keeping uncontrolled ventilation to a minimum in buildings equipped with balanced ventilation. Provides theoretical and experimental description of leakage of air past windows. Includes comparison between standards of different countries. Discusses effect on building ventilation of variations of wind and outdoor temperature. Considers in conclusion measurement of air flows between rooms in a building. Describes development of tracer gas method based on computer-assisted evaluation.

Instrumentation and analysis of full-scale wind pressure measurements,

Describes instrumentation used to measure wind pressure on two tall buildings in central London. Describes pressure transducer which gives an electrical output suitable for use in conjunction with standard types of commercial recording equipment. Describes site installation and recording equipment which produces multi-channel records in ultra-violet sensitive photographic paper. The records are processed and digitised and several computer programs have been written to analyse this data.

Automated air infiltration measurements and implications for energy conservation

Gives theoretical justification for the use of tracer gas method for measuring air infiltration. Describes automated instrumentation system using sulphur hexafluoride as a tracer gas. The system consists of an electron capture detector, an automation unit, an SF6 storage and injection panel, a cassette recorder and corresponding plumbing and tanks. Gives examples of field use of system.

An automated air infiltration measuring system using SF6 tracer gas in constant concentration and decay methods

Describes a system which measures the rate of air infiltration in buildings using sulphur hexafluoride as a tracer gas. Discusses two methods for evaluating the infiltration rate,the decay method and the constant concentration method. The system automatically operates a portable electron capture detector /chromatograph and samples air on a one-minute cycle. In the decay method the slope of concentration vs time on a semilogarithmic plot can be used to compute infiltration rate.

Pages