Investigation of the performance of gypsum sheathing.

The computer program EMPTIED was used to assess the moisture performance of representative brick veneer and exterior insulation finish system (EIFS) walls under the climate conditions for fifteen locations in Canada The indoor conditions were assumed to be those expected in a one-bedroom apartment occupied by two persons which was ventilated with outdoor air at a constant rate of 0.3 air changes per hour.

Ventilation concept, indoor air quality and measurement results in the "Passivhaus Kranichstein".

The "Passivhaus Darmstadt-Kranichstein" is a 4 unit terrace house with an extremely low total annual energy consumption of less than 32 kWh/m² of living area, thereof about 12 kWh are needed for room heating /Feist 1994/. The determinig factors for the low consumption are the superinsulation, airtightness of the thermal envelope in combination with a highly efficient VAV ventilation system, and an improved window construction. The "Passivhaus" therfore is a typical example of an improved low energy house.

The performance of dynamic insulation in two residential buildings.

In order to reduce the heat loss from buildings it is common to increase the thickness of insulation in the building envelope.The consequence of this action is more expensive buildings. Building regulations in countries with cold climate require U-values far the envelope which results in thicker and therefore often stronger constructions than needed for structural capacity. Another strategy to save energy has been to reduce the ventilation rates in buildings.