The Influence Of “Ventilate Sill” Design As A Device To Improve Natural Ventilation Inside School Buildings In Hot And Humid Climate

This article is part of a research in progress about comparative study methods for the Brazilian reality using among many other authors, Givoni (1969), Voght and Miller-Chagas (1970), Fanger-ISO(1970), ASHRAE (55-1992), Mahoney (1971), Humphreys (1978) and Olgyay (1962) methods. This research presents the principal concept to be evaluated by the Universal Fuzzy Controlled aiming to establish a reference to determine a possible interference of the acclimatization factor to determine thermal comfort.

Schools: All problem buildings?

Seven schools underwent an energy audit, evaluating the existing situation through measurement and simulation and looking to possible retrofit measures and their economic feasibility with the energy performance tool (EPB) as an instrument. The results are troubling. The seven schools audited are all problem buildings: hardly any insulation, windows quite air leaky, central heating systems poorly designed and no usage of an on purpose installed ventilation system.

The optimisation of operation of HVAC-systems in industrial buildings based on results of energy audit.

Analyses the operation and life cycle costs of industrial buildings using an energy and environmental auditing process. The results will be used in the design of optimized HVAC systems for the future.

Integrated building performance simulation.

This paper justifies the need for an integrated approach to building performance assessment and provides examples of the technical appraisals that may then be enabled. The contention is that the use of design tools which focus on a single domain will result in sub-optimum design solutions in terms of indoor air quality, occupant comfort, energy use and environmental impact.

Main features of the energy performance regulation in the Netherlands.

The Building Regulations with regard to the energy performance of buildings in the Netherlands is an attempt to a performance oriented requirement in conjunction with a test standard. The test standard in fact means a calculation procedure. The requirements are given in the Dutch Building Decree. This Decree is coupled to the building act. Within the scope of an application for a building permit is has to be proven that the energy use of the building does not reach the maximum allowed energy amount set for that building.

A simple interface to computational fluid dynamics programs for building environment simulations.

Presents a simplified CFD interface (SCI) intended to allow architects and building engineers to use CFD with little training. It can be easily integrated into new CFD programs.

Comparison of Windows and DOS versions of the DOE2 in simulating a passive building.

Visual DOE is a Windows interface version of the DOE2 simulation program. Its purpose is to help save time in writing BDL input for the simulation. As its calculation engine is the same as DOE2 in the DOS version, DOE should result in the same output as the DOS version. However, difficulties arise in identifying the building's configurations, materials and construction and systems in the two input versions. While modeling a simple one-story Hpassive H building, it was difficult to get a good match in the simulation results in the two versions.

Probe 3.