Solar shading devices can significantly improve thermal comfort and reduce cooling loads and potential glare problems in highly glazed buildings. This paper describes results from an extensive measurement program that started in 1997, covering external shading devices, products placed between two panes (interpane), and internal shading devices. Measurements of the total solar energy transmittance (g-value) have been performed using a double hot-box arrangement placed in a real climate.