1994 Survey of current research into air infiltration and related air quality problems in buildings.

Provides a platform for the dissemination of information related to infiltration, ventilation, indoor air quality and energy use within buildings by means of a survey and analysis of current research. The current survey reports on research projects from over 250 sources worldwide. The sections include an analysis of the results of the survey, a detailed list of survey replies, which is also available in searchable database format, and contact names and addresses for researchers.

The Dutch E Novation Program: indoor air quality in dwellings before and after renovation.

The Dutch E novation program is a national demonstration program in which dwellings with high energy consumption, moisture and mould problems and poor indoor air quality were renovated, with special attention to the selection of the heating and ventilation systems, thermal insulation and the building physical details. A number of indoor air quality parameters were monitored before and after renovation, showing an important improvement in the indoor air quality.

The indoor air quality and the ventilation performance of four occupied residential buildings with dynamic insulation.

Dynamic insulation has been used in non domestic buildings for 20- 30 years in order to reduce the heat loss and to bring preheated air into the buildings. Dynamic insulation means a construction where the air is being forced through the insulation, usually from the colder outside air into the heated building. The Norwegian Building Research Institute has been engaged to evaluate 12 row houses, with dynamic insulation used in the roof, which has been built in the Oslo area. 4 of the houses were monitored over a period of time.

Measurement and CFD modelling of IAQ indexes.

So as to better understand and predict IAQ problems, the velocity field and distribution of local mean age of air were determined experimentally with three-dimensional anemometry and decaymode tracer gas measurements inside a classroom. We also performed 3-D numerical simulations of the velocity field in this room, using a CFD code. The time dependent concentration decay of tracer gas was simulated using the previously determined flow field in the pollutant transport equation. Relatively good agreement was found between the simulated and experimental concentration decay curves.

Determining IAQ dynamic response to emissions.

To achieve acceptable indoor air quality (IAQ), ASHRAE Standard 62-1989 recommends the use of the alternative IAQ procedure. The IAQ procedure can treat both constant-volume and variable-air-volume (VAV) with constant or proportional outside airflow rates. The relationships in Appendix E of the standard must be used in conjunction with the IAQ procedure to directly calculate indoor air contaminant concentrations in an occupied space.

A laboratory for investigation of the air quality in simulated indoor environments.

A laboratory, designed to form the basis for research aiming at increasing the knowledge concerning the interactions between indoor pollution sources and the indoor environment, has been taken into operation. One long term purpose of the activities in the laboratory is to develop theoretical models, based on experimental data, for the prediction of the air quality in real buildings. At present, the experiments focus on the relationship between the emission of pollutants from building materials and the environmental parameters, i.e.