Analysis of air change rates in Swedish residential buildings.

Measurements on the rate of air exchange in residential buildings have been carried out by the Swedish Institute for Building Research since 1970. The results of an analysis of these measurements are presented in this paper for about 500 buildings not having mechanical ventilation. The studied buildings include one- and two-storey, detached, single- family houses, row houses, and multifamily residential buildings built between 1900 and 1982 and of various design. In some cases, the buildings have been retrofitted by improving the insulation of the attic or the exterior walls.

Air leakage and fan pressurization measurements in selected naval housing.

Data from detailed tracer concentration decay and induced pressurization measurements were obtained in tests of duplex and row apartments at Norfolk, Virginia and Pensacola, Florida to accurately determine air leakage characteristics of selec

Measurement of infiltration using fan pressurization and weather data.

Presents a technique using fan pressurization results and weather data to calculate infiltration. The geometry, leakage distribution, and terrain and shielding classes are combined into two reduced parameters which allow direct comparison of wind-induced and temperature-induced infiltration. Using these two parameters and the total leakage area of the structure (found from fan pressurization) the infiltration can be calculated for any weather condition. Presents experimental results from 15 different sites for comparison with theoretical predictions.