A review of weather data for natural ventilation.

This paper briefly reviews the weather data available for natural ventilation and briefly reviews hourly data for simulation. It starts by reviewing the need for basic data for initial manual calculations. It then discusses the hourly weather data available for example the UK CIBSE Example Weather Years, and the European Community Test Reference Years. These are mostly selected for energy analyses rather than design, but there is still aneed for establishing general criteria for weather data for design of HVAC services and natural ventilation.

Two-zones model for predicting passive stack ventilation in multi-storey dwellings.

Proper dimensioning of natural ventilation system for multi-storey buildings is a critical matter, because the air flow rate depends on many parameters as outdoor temperature, wind, distribution of air inlets and envelope air leakage, characteristics of outlets and cowls. The computer code GAILNE BIZONE predicts the ventilation rates in multi-storey dwellings equipped with passive stack ventilation system. Each level is treated as a two-zones configuration, but each zone is linked to the collective ventilation shaft of the building.

The role of infiltration for indoor air quality

Multifamily buildings with natural ventilation are still being built and exploited. Such buildings are often equipped with individual gas-fired water heaters located in windowless bathrooms. It implicates the possibilities of improper gas exhaust as a result of the decrease of infiltration, what could be sometimes even harmful for the occupants' health. Based on the numerical simulations, analysis of ventilating air flows in typicalmultifamily dwelling house will be carried out.

Reducing air infiltration losses in naturally ventilated industrial buildings.

The UK factory stock is predominantly naturally ventilated. Measurements performed in this class of building have indicated that air infiltration rates in factories are usually excessive in relation to occupants' requirements for health and safety, resulting in an energy penalty. As part of a project to investigate construction options for energy efficient industrial buildings, three factories of different cladding construction types were designed and then built at Aberarnan, South Wales.

Natural ventilation through a single opening - the effects of headwind.

The airflow between a warm room and cool exterior can be significantly affected by an external headwind. Pollutant concentrations within the space depend on the relative sizes of the wind and the undisturbed stack driven flow. Two scenarios are described. Firstly, a space is filled initially with buoyant polluted air. The space is then naturally ventilated through a single opening. In the "no wind" case, a gravity current of external air flows into the space. All the polluted air is expelled from the room.

Investigation of ventilation conditions in naturally ventilated single family houses.

The reason for the present project is the need for more reliable information about the actual ventilation conditions in naturally ventilated, detached houses. The aim has been to quantify the ventilation and humidity conditions and to establish a better basis for elaborating directions and guidelines on proper ventilation of detached houses. A national questionnaire survey covering more than 2100 households has been carried out, together with detailed investigations in about 150 houses.