Since many years, several monitoring studies have shown that the quality and compliance of installed ventilation systems can be low. The recently developed Evaluation scheme in Belgium tries to tackle this problem, thanks to the mandatory Ventilation Performance Report of all new ventilation installations, to be delivered by a Ventilation Reporter recognised by a Third-Party control organisation. This factsheet describes the approach of this scheme, including the penalty scheme and the role of the actors involved.
Submitted by Maria.Kapsalaki on Thu, 03/09/2017 - 11:56
Ductwork airtightness is an input parameter in the French energy performance calculation method for new buildings (RT 2012) which influences the energy performance rating. If the ductwork airtightness class used in the calculation is better than the default value (2.5*class A), the ductwork airtightness has to be justified in accordance with a third-party testing scheme operational since 2014. Furthermore, there is a minimum ductwork airtightness requirement set to leakage class A if the building applies for the Effinergie+ or BEPOS labels.
Submitted by Maria.Kapsalaki on Thu, 03/09/2017 - 11:53
Systems providing space heating, ventilation, space cooling and/or domestic hot water (HVAC) to residential or commercial buildings are playing a major role in the building energy performance. Eurovent Certita Certification manages a voluntary certification of the performance of heating, ventilation and air conditioning products, under the European mark “Eurovent Certified Performance”. Such a certification increases confidence in the published performance data of products and provides an easier access to input data for calculation of a building’s energy performance.
Submitted by Maria.Kapsalaki on Thu, 03/09/2017 - 11:50
Since 2006, the Effinergie certification has been a major market driver in France for energy efficiency initiatives in all building types, new and renovated. It has been a laboratory for the 2012 energy regulation in France, for instance, for the overall primary energy minimum requirements or for the mandatory justification of an envelope airtightness level. In the same vein, the Effinergie+ and Bepos labels operational since 2012 and 2013 experiment new requirements and methods, which will serve for the 2020 revision of the energy regulation.
Submitted by Maria.Kapsalaki on Thu, 03/09/2017 - 11:48
Because of the relative complexity of the French method for calculating the energy performance of new buildings, the selection of input data for heating, ventilation and air-conditioning (HVAC) systems can be a challenge without any guidance.
Submitted by Maria.Kapsalaki on Thu, 03/09/2017 - 11:45
Building air leakage rate is taken into account in energy calculations, but mainly with default tabulated values. With tabulated values, there is an option to use measured values instead of more conservative tabulated values. Regarding compliance, usually there is no requirement to measure and verify the building air leakage rate (except in France).
Submitted by Maria.Kapsalaki on Thu, 03/09/2017 - 11:43
Airtightness performance of the building has a significant weight in the Belgian EPB-calculation and the number of pressurisation tests in new buildings is strongly increasing. To face the potential lack of tester’s skills and to ensure a reliable value, a quality framework has been achieved according to which testers have to pass an exam and could be controlled. This factsheet describes the relevant quality framework and its context.
Submitted by Maria.Kapsalaki on Thu, 03/09/2017 - 11:40
AMA (General material and workmanship specifications) has been used in Sweden for more than sixty years. The different parts of AMA are used as reference documents in technical specifications. Between 90 and 95% of all building projects in Sweden refer to AMA in the contract documents.
Submitted by Maria.Kapsalaki on Thu, 03/09/2017 - 11:37
Since 2006, there has been a significant reward in the French energy regulations for good airtightness, which has been combined with a minimum requirement for residential buildings in the 2012 version of the regulation. Airtightness test results show that the average building airtightness performance has improved by nearly 50% in single- and multi-family buildings since 2006 and now stabilises below the minimum requirements around q50 = 2.8 m3/h per m2 of envelope area, excluding lowest floor (or about n50 = 1.8 h-1).
Submitted by Maria.Kapsalaki on Thu, 03/09/2017 - 11:34
Regulatory compliance checks on samples of residential ventilation systems are operational in France. The analysis of their results shows a significant rate of non-compliance with the ventilation regulation (rate on the order of 50%).