The influence of outdoor air vents and airtightness on natural ventilation - calculations based on measurements.

Many modern buildings in the Nordic countries have mechanical ventilation. Passive stack ventilation is, however, an accepted ventilation system in the Nordic countries according to the current building codes. The building authorities need to be able to supply guidelines on natural ventilation systems in modern buildings, in order to fullfill the requirements on a healthy indoor climate at a reasonable energy cost. Therefore a project was initiated by the Nordic committee on building regulations.

Evaluation of a controlled natural ventilation system.

The project described in this paper has performed simulations using a multi-zone air flow model (4(COMIS)) of three different passive stack ventilation systems. The objective of the simulation calculations was to evaluate system performances and to make suggestions for possible improvements of the systems.