Influence of air infiltration on heat losses in multi-family dwelling houses.

The paper presents a proposal of numerical procedure for air flow simulation in multi-zone buildings (up to 100 zones). This procedure can work with 1 hour time-step according torequirement of TRNSYS-a well-known modular system simulation programme. Co-operation between TRNSYS and my own programme is analysed, taking a typical Polish 5-storey dwelling house as an object of simulation. The proposed numerical procedure can also be run as an independent programme calculating the ventilation air flow, air change rate and heat losses due to infiltration.

Ventilation-energy liabilities in US dwellings.

The role of ventilation in the housing stack is to provide fresh air and to dilute internally-generated pollutants in order to assure adequate indoor air quality. Providing this ventilation service requires energy either directly for moving the air or indirectly for conditioning the outdoor air for thermal comfort. Different kinds of ventilation systems have different energy requirements. Existing dwellings in the United States are ventilated primatiy through leaks in the building shell (i.e., infiltration) rather than by mechanical ventilation systems.

Ventilation rates and air tightness levels in the Swedish housing stock.

This paper reports results from the ventilation and air tightness measurements in Swedish dwellings as part of the 1992 Swedish Energy and Indoor Climate Survey (the ELIBstudy). The indoor climate in a random sample of 1200 single- and multi-family houses from the Swedish housing stock were investigated. Among different parameters the ventilation and the air-tightness of the houses were measured.

Theoretical basis for assessment of air quality and heat losses for domestic ventilation systems in France.

Ventilation of buildings is necessary, both to insure adequate indoor air quality and to protect the building itself against condensation and mould growth. On the other hand, ventilation rates must not lead to excessive energy consumption. French regulation doesn't appreciate directly the indoor air quality but fixes requirements for the value of exhaust stale air in service rooms ; furthermore heat losses related to cross ventilation due to wind effects are also taken into account.

Moisture Admittance Model: Measurements in a Furnished Dwelling.

The BRE method of predicting water vapour conditions in houses is based on two generalised moisture admittance parameters a and p. Previous laboratory experiments suggested that it is possible to determine these coefficients for an unfurnished room with wooden panels, using measurement periods of six hours under dynamic equilibrium conditions. The present study explores the possibility of using such conditions to determine a and P in-situ for the living-room and bedroom of a furnished flat of conventional construction.

Assessment of energy impact of ventilation and infiltration of the French regulations for residential buildings.

Ventilation is necessary to insure acceptable indoor air quality as well as to protect the building itself against damage due to condensation Ventilation rates however, must not lead to excessive energy consumption In order to comply with these requirements of hygiene, comfort and energy savings, French regulations stipulate that the ventilation of dwellings has to be general and continuous and achieved by specific systems by which fresh air is provided to the dwellings.