The Aardvark automated system has been developed for continuously measuring the air-exchange rate and 222Rn (radon) concentration in an occupied residence. The air-exchange rate is measured over 90 min intervals by tracer gas decay using sulphur hexafluoride as the tracer gas.
In Sweden there are two major sources to indoor radon, the building material and radon from uranium rich soils. It is now widely accepted that indoor radon daughter concentration in Sweden, higher than 1000 Bq/m3 is most frequently caused by
Reports tests of a scintillation counter to detect Ra 222 in air and water. The counter consists of a spherical cavity coated with ZnS(Ag) powder, built in a lucite cylinder whose external surfaces, excepting the window which is put in contact with a photomultiplier, are made reflective with a special paint. The performance of the detector has been analysed with respect to size,efficiency, background, constant activity and constant concentration in the sample. Finds that for liquid samples, two different values for the diameter, 5 cm. and 7.5 cm.