Zone to zone tracer gas measurements; laboratory calibration and values of air flows up and down stairs in houses.

This work is concerned with measuring air flows between the floors of houses. A simple measuring technique is described in which two portable SF6 systems were employed. The design and construction of the portable system are presented. A comparison of air flow patterns in a superinsulated house and a standard house is made. Results showed that the air flow between the upper and lower floors of the superinsulated house was about 20 m3/h compared with 100 m3/h in the traditionally built house.

Integral mass balances and pulse injection tracer technique.

Tracer gas techniques for measuring airflow rates in building systems are considered. These techniques are classified in terms of tracer gas injection strategy employed and mass balance relationships used to analyze measured tracer concentration data. The discussion focuses on one class of tracer techniques - the pulse injection techniques - based upon pulse injection strategies and integral mass balance relationships.

Natural airflows between roof, subfloor and living spaces.

This paper is concerned with natural air flows between major construction cavities in New Zealand houses. A two tracer technique was developed to measure infiltration rates in the subfloor (crawl space), the living space and roof space, together with air flow rates connecting these zones. Five experimental houses were chosen to represent expected extremes in air flow resistance between subfloor and roof space.

Constant concentration measurement with two tracers.

The technique of tracer gas measurement has during recent years tended towards increasingly complicated measuring methods. The new measuring techniques are essential in order to procure more information about the circulation of air through buildings, or in order to perform more accurate measurements in large and complex buildings. The measuring method by means of "constant concentration of tracer-gas", which has been applied at Technological Institute for about 7 years, has proved to be a very accurate measuring method for both small and very large buildings.

Commercial building ventilation measurements using multiple tracer gas.

A unique multiple tracer experimental system has been developed and utilized within commercial buildings to monitor ventilation rates, air exchange efficiency, ages of air (at multiple indoor locations), flow rates of supply and outside air, and percent outside air in supply airstreams. The multiple tracer technique also makes it possible to determine the fractions of air at a monitoring point that entered the building through a particular air handler and by infiltration.

Ventilation in industrial buildings. Final report.

             

Measuring air change rates.

   