The ventilation system of a 60 seats conference room was retrofitted to improve indoor air quality. The old, mixing type installation was replaced by a displacement ventilation system. However, the building layout did not allow an optimum location of air inlets and outlets. It was therefore interesting to measure the actual performance of the new system. Using tracer gas techniques, the age of air was mapped within the room, and the ventilation effectiveness was measured in various configurations. The actual air flow rates were also measured in the ventilation system.
The present paper deals with one of the most important mechanisms of inter-zone mass and energy transfer, namely the buoyancy-driven flows through stairwells that connect the floors of buildings. To further investigate these phenomena, experimental as well as theoretical studies have been carried out. A series of experiments have been performed in order to study the airflow through a typical stairwell that connects the two individual zones of a two-storey house. Airflow rates between the two zones were measured using a single tracer gas decay technique.
The Netherlands Agency for Energy and the Environment(NOVEM) is conducting a program for the implementation of Low Temperature Heating (LTH) systems in buildings. The primary goal is to enable the use of Low Talued Energy as a heating source. Major savings in enery consumption can be realised by fully utilising the potential of Low Valued Enery. Besides the argument of savings in energy supply, there are additiond benefits in the fields of. Indoor Air Quality (particles, mites, lower air temperature, annoyance and dust);.
Air conditioning is widely used in the office building sector in the French Mediterranean region. Though often a «sine qua non» for renting office space, there is however a widespread feeling that operating and maintaining air-conditioning systems can be troublesome (unreliability, regulation and maintenance difficulties, non uniform comfort conditions, high prices are frequently lamented).
Low energy buildings should satisfied two main tasks: to assure a low energy use and provide an excellent residence comfort. The building envelopment elements, especially the transparent one, have major influence on both tasks. The paper presents research results of heat transfer and fluid flows through double pane window with tight, opaque insulation screen. The insulation screen was installed in such a way, that a semi open air gap was formed. An air gap is connected with the building interior through an opening on the bottom and with exterior through siphon at the top.
Ventilation is essential for the maintenance of good indoor air quality, although there is evidence to suggest that energy loss through uncontrolled or unnecessary air infiltration is excessive. In this study, estimates are presented for air change (ventilation and infiltration) energy use in non-industrial buildings for 13 countries. Various methods are used for the estimates, but they are mainly based on calculating the total annual enthalpy change needed for the conditioning of air. The potential for reduced energy use by improved ventilation control is also briefly reviewed.
In designing thermal and ventilation systems in buildings, an examining process of exchange between the designers and analysts is needed. This study aims to expand the simulation system of thermal and ventilation into an automated process for the design of optimum thermal and ventilative conditions, based on the expertise of analysts, the analysis of the thermal environment and the modification of the design, by automating these functions.
The present paper investigates the potential of night ventilation techniques when applied to full scale office buildings, under different structure, design, ventilation, and climatic characteristics. The approach of this study includes the use of both experimental data and theoretical tools in order to determine the impact and the limitations of night ventilation regarding the thermal behavior of various types of office buildings.
In a cold climate such as of Montreal the air infiltration through the exterior envelope of a house has a significant impact on the heating energy consumption and cost. Although the reduction of the air infiltration rate to the level of new well-built houses can lead to the reduction of heating energy cost, the present cost-effectiveness of its implementation in the existing houses is low. The evaluation of the environmental impact of this energy conservation measure is performed using the GWP (Global Warming Potential) index.