Ventilation rate measurement.

Some guidelines on indoor-air quality specify a maximum allowable exposure to CO2. In a room ventilated by a mechanical extract system a control program on the CO2 concentration may, by anappropriate sampling strategy, supply information about the exhausted flowrate. This paper briefly outlines a simple analytical model for estimating the exhausted flowrate by measuring the CO2 concentration and keeping a record of the occupancy of the room.

Research report from Czechoslovakia: The influence of infiltration on the heating of a building.

The task of this study is not the analysis of these influences when calculating the heat losses. Instead the influence of wind and temperature on the total heat losses at 1% probability exceedance of the heat losses is being investigated. Thecalculation is based on the correlation of the outdoor temperature, the wind speed and its direction, the transmission coefficient correlation and the air-leakage of the curtain wall.

Power law rules - OK?

The object of this article is to compare the performance of these two flow representations against a small set of measurement data using the concepts outlined in the Air Infiltration and Ventilation Centre's Calculation Techniques Guide.2 A particular aspect of the approach presented is that in each case an identical solution technique, flow network and pressure field has been applied, thus enabling a direct comparison of each of the flow representations to be made. The tests were by no means exhaustive and further evaluation is recommended.

Air infiltration and ventilation calculation techniques.

A range of calculation techniques is available for the calculation of air infiltration and ventilation in buildings. The choice is largely dependent on intended application, while the level of complexity ranges from straightforward empirical techniques to detailed multi-zone numerical methods. The objective of this article is to outline some of the techniques currently available and to indicate the purposes for which they are most suited.

The determination of leakages by simultaneous use of tracer gas and pressurization equipment.

The air leakage distribution in a building is, in certain circumstances, difficult to determine. One example of this is the ceiling of the dwelling illustrated in figure 1 and 2. It is almost impossible to make the ceiling perfectly airtight; thismeans that a measurement by difference is impossible. The inclined roof is not airtight at all. A rather simple and easy technique is to perform measurements using tracer gas and pressurisation equipment at the same time.

The validation of a multiple tracer gas technique for the determination of airflows between three interconnected cells.

This paper describes the extension of the previously described UMIST technique for the determination of airflows between two interconnected cells to the case of three connected cells, and gives the results obtained for a series of validation experiments carried out under controlled conditions.

Air movement - a numerical prediction technique.

Air movement within enclosures, which may result from a combination of infiltration, mechanical ventilation and convective heat transfer effects, is important for considerations of thermal comfort, ventilation efficiency and energy conservation.

Air leakage characteristics and new standards for Swiss construction.

In the last few years energy regulations have been introduced in many Swiss Cantons. The main goal of these regulations, relative to the building envelope, is to improve the insulation value. Consequently, typical current construction for new buildings is characterized by exterior wall and roof insulation U-values under 0.5 W/m2.K and windows with triple glazing or its thermal equivalent.

The analysis of single-sided ventilation measurements.

Because of the wide range of parameters (wind speed and direction, temperature difference, position and characteristics of flow paths, building shape and location) which determine natural ventilation, obtaining useful design information from field measurements presents many problems. This note provides an approach for analysing the results of field measurements of single-sided ventilation. The background to the measurements and associated theoretical and laboratory studies of possible physical mechanisms for single-sided ventilation are presented fully elsewhere.

Research report from Norway: Wind pressure measurements on a rotatable test house.

At the Norwegian Building Research Institute, Division Trondheim, we have been working on a research project involving wind pressure measurements. The main goal of the project is toget more information about the influence of wind pressure on the heat loss from timber frame walls with ventilated airspace between the wind barrier and the cladding. The project is divided into three parts: calculations, hot-box measurements and wind pressure measurements.

Pages