Energy-saving Effect of Thermal Energy Storage Using Introduced Outdoor Air

Recently, buildings with thermal energy storage system have increased because of its economic advantage. In thermal energy storage system using introduced outdoor air, building masses are used as thermal storage media and cooled by outdoor air introduced by a mechanical fan in night-time. In spring and autumn, the cooled building masses can work to reduce cooling load in day-time. In this study, the stored heat was calculated by using simple heat transfer models for various building masses, and the energy performance of this system was evaluated quantitatively by system simulation.

A Study on the Hybrid Air-conditioning system Coupled with Radiant Floor Cooling and Ventilation System

In this study, the concept of the Hybrid air-conditioning system utilizing convection and radiation heat exchange will be suggested. In this paper, the heat removal characteristics of Hybrid air-conditioning system will be described by theoretical review and experimental methods. Also the ratio of cooling load removed by Hybrid air-conditioning system could be divided as radiation and convection heat exchanges. The methods could be used to system design of Hybrid air-conditioning system.

Thermostat/Hygrometer vs ANN-Based Predictive/Adaptive Environmental Control Strategies

This study tested the feasibility of employing artificial neural network (ANN)-based predictive and adaptive control logics to improve thermal comfort and energy efficiency through a decrease in over- and under-shooting of control variables. Three control logics were developed: (1) conventional temperature/humidity control logic, (2) ANN-based temperature/humidity control logic, and (3) ANN-based Predicted Mean Vote (PMV) control logic.

Investigation of the Usage of Ground Source Heat Pump System on Wall Heating

Wall heating systems are more preferable heating systems than other conventional systems due to their low temperature operating ranges. These systems are equipped with heating serpentines or panels where the water is circulated and the serpentines are mounted on the walls of rooms. Ground source heat pump systems are todays one of the useful renewable energy based heating systems.

Simple error reduction in tracer-gas field-measurements of air handling units

Tracer gas measurements are an unparalleled means of measuring air recirculation, leakage, and air flow rates in air handling systems [1-5]. However, such measurements are subject to significant measurement uncertainty in field conditions. A common problem is imperfect mixing of tracer gas.

A Proposal of Hybrid Ventilation System Using Stack Effect in High-rise Buildings

This study proposes the hybrid ventilation system and its design methods for high-rise buildings. The proposed hybrid ventilation system uses natural driving power for ventilation based on air flow in the whole building and indoor and outdoor pressure distributions. Furthermore, it solves the troubles of the conventional natural or mechanical ventilation systems. This paper presents theories and a process for duct design for natural ventilation which forms the basis of a hybrid ventilation system in high-rise buildings.

CFD Analysis on Capture Efficiency in Commercial Kitchen using Low Radiative Cooking Equipment with Concentrated Exhaust Chimney

In a commercial kitchen, a large ventilation rate is needed and energy consumption can be large because a large amount of effluence of heat and moisture need to be removed. To improve kitchen environment and to save the energy, low radiative cooking equipment with concentrated exhaust chimney was developed. Although a ventilation rate may be decreased by using this equipment, the effluence needs to be captured well. To predict indoor air and thermal environment of commercial kitchen using this equipment, CFD analysis is useful.

Influence of Partition Curtain on Vertical Profile of Temperature and Contaminant Concentration in Sickroom with Displacement Ventilation

For patients, the sickroom is a place where they receive medical treatment and also a living space where they spend most of time in a day. Therefore, good indoor air quality and comfort should be kept in sickroom. We propose to use the displacement ventilation as a means of obtaining high indoor air quality in sickrooms. The purpose of the study is to examine the validity of this system. This paper shows the experiment results and CFD analysis results to examine the effect of partition curtain in the displacement-ventilated room.

Prediction of Plume above Residential Cooking Range by means of CFD analysis

Recently, Island kitchen is installed in many houses in Japan. In the island kitchen, the cooking range is placed on the island unit, and the center hood is located above the cooking flow in the room. In such a kitchen environment, there is a possibility that cross winds or other disturbing flow may reach the cooking zone. For this reason, pollutant fumes from the cooking range may be diffused to residential zone. CFD analysis is an effective measure for comprehending such a diffusion of the thermal plume.

Performances of new innovative domestic ventilation systems in combination with low temperature floor heating

In extended laboratory measurements, the combination of new innovative domestic ventilation systems with low temperature heating is investigated, using the advanced EnoTemp measurement equipment. These measurements took place in the framework of a large Dutch demonstration project for these innovative domestic ventilation systems. The main conclusion of the laboratory measurements is that self-regulating façade grilles form a good combination with low temperature heating in terms of thermal comfort.