Ventilating multiunit residential buildings

Ventilation strategies for multiunit residential buildings are described according to the results of a survey in 260 randomly selected buildings in Canada. Most buildings use corridor pressurization systems with an either central or apartment-based air exhaust. Some outdoor air is delivered to individual apartments, but in some cases, corridor air systems act as a ventilation system for individual apartments. Occupants complaints have been recorded, the main one being odor transfer between apartments.

New requirements of standard 62-2001

This article presents the new requirements of the ANSI/ASHRAE standard 62-2001, Ventilation for Acceptable Indoor Air Quality, including recent changes of the standard available at the Ashrae web site. It explains the status of the 31 addenda to the 1999 version of the standard, some of them being included in the 2001 version, others being still in discussion or in the process to be adopted.

Numerical calculation of view factors and radiant temperature for complex room geometry

This method enables the determination of the influence of heating source characteristics on mean radiant temperature for composite room surfaces, as well as on thermal comfort and discomfort. A maximal possible thermal comfort area can be achieved with the determination of the best interactive influence between the building structure and its heating system.

Parametric study in a linear atrium by using CFD : the impact of vaious parameters on thermal behaviour

The objective of this parametric study is to vary some parameters related to the conception of an atrium in order to analyse through CFD calculations their impact on the thermal behaviour during the critical summer conditions. The guideline produced are intended to help the architects especially at the first stage of the conception process.

A single tool to assess the heat and airflows within an enclosure : preliminary test

The results of a study testing the possibility of using Dynamical Thermal Modelling (DTM) techniques within CFD are reported in this paper. Two test procedures (an extensive one and a simplified one) were conducted for the modelling of an enclosure, to model heat exchanges through building materials and effects on internal temperatures and air flows.

Computational Fluid Dynamics (CFD) validation of the prediction of pesticide dispersion in a naturally-ventilated building

Full-scale laboratory measurements combined with numerical simulations were undertaken to evaluate CFD capability to predict the pesticide dispersion in a naturally ventilated building. CFD successfully reproduced the trends but overestimates the mixing inside the building.

Flow fields and particle trajectories in turbulent type clean rooms with different supply/exhaust air arrangements

A wall return and a ceiling return air arrangements of turbulent type clean rooms are presented in this paper. The influences of obstacles on the flow fields are compared by a numerical simulation.

Airborne particle concentration control for an operating room

Critical parameters such as the particle source location, air supply inlet design, operating table location, and lamp design are responsible for the particle distribution within the operating room, they have been investigated by means of CFD.

Particle concentration calculations using CFD - a comparison -

CFD is a suitable tool to calculate concentration in particle contaminant distribution in a room. 3 approaches are described for two types of flow problems and compared in this paper.

The effect of enclosure size on turbulence in axisymmetric jets

The paper presents the results of the measurement of turbulence intensity in jets issued into enclosures of different size. The test results confirm the relation between the velocity distribution coefficient and turbulence parameters.

Pages