Greater London Council
Year:
1980
Bibliographic info:
GLC Development and Materials Bulletin no.126 item 5

Discusses condensation within dwellings. Treats conditions conducive to reducing risk of condensation, factors which control concentration of water vapour in the air in a building and temperature of building fabric. Distinguishes between those under control of occupier and those controlled by design of building fabric. Considers in particular effect of ventilation on dewpoint of the air in bedrooms and humidity and temperature conditions in a bedroom during the day. Provides several case histories which illustrate relationship between ventilation and condensation.