Burch D.M. Lemay M.R. Rian B.J. Parker E.J.
Year:
1984
Bibliographic info:
Preprint ASHRAE 1984 Annual Meeting Kansas City USA 17-20 June 1984 17pp. 10 figs. 6 tabs. 4 refs. #DATE 17:06:1984 in English

A small test house having a pitched roof/ventilated attic was installed in a high bay environmental chamber. The test house and its attic were extensively instrumented for measuring heat and moisture transfer. The test house was exposed to a ser