Discusses insulation of lofts, roofs, walls, windows and floors, natural ventilation of dwellings and mechanical ventilation with heat recovery in dwellings. Considers cost benefits of weatherstripping and constant-flow ventilators for naturally ventilated houses. Concludes that installation of mechanical ventilation with heat recovery is uneconomic, but adding a heatexchanger to an existing mechanical ventilation system has economic benefits.
An economic assessment of some energy conservation measures in housing and other buildings.