Tarumi H, Fujii S
Year:
1990
Bibliographic info:
UK, Energy and Buildings, Nos 15-16, 1990/91, pp 609-616

In this paper, the conversion of exhaust heat to latent heat is studied as one of the methods for the preservation of the thermal environment in urban areas. A simulation model of exhaust heat management is composed and applied to the soot-and-smoke emitting facilities in the Tokyo Metropolitan Area. The effectiveness is estimated by indices of "coefficient of exhaust heat management" and "conversion ratio of exhaust heat to latent heat".