Breathing walls were installed on opposite sides of a scale mock-up model of a housing structure that was situated in an artificial climate test room. We analyzed the thermal insulation capability. heat recovery effect and indoor climate for the inflow of outdoor air across the breathing wall. The rate of heat recovery reached 30% under strong winds of up to 8 mis. Even when the ventilation rate tripled due to the strong wind, the temperature difference in the vertical direction was less than 2 K.
Effects of the inflow of outdoor air through a breathing wall on thermal insulation properties and indoor climate in winter.
Year:
1999
Bibliographic info:
in: PLEA '99 "Sustaining the Future - Energy, Ecology, Architecture", proceedings of a conference held Brisbane, Australia, September 22-24, 1999, edited by Steven V Szokolay