Condensation on windows creates obscured view, can cause building damage, and may lead to mold growth and poor indoor air quality. The Canadian Standards Association (CSA) has developed new procedures to evaluate window condensation potential, using a combination of computer simulation and testing. This paper summarizes results of a study into various aspects of computer simulation related to the evaluation of condensation potential. These findings were used to assist in the development of the CSA procedures.
Computer simulation of window condensation potential.
Year:
1998
Bibliographic info:
USA, Atlanta, American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE), 1998, proceedings of "Thermal performance of the exterior envelopes of buildings VII" a conference held Sheraton Sand Key Hotel, Clearwater Beach, Florida