A simplified method was investigated for estimating the dynamic pressure tangential to an opening (Pt) with Irwin’s surface wind sensor. The wind velocity measured by this sensor was broadly consistent with the value measured by a hot-wire anemometer. Mor
Local dynamic similarity concept as applied to evaluation of discharge coefficients of ventilated buildings. Part 3: Simplified method for estimating dynamic pressure tangential to openings of cross-ventilated buildings

Year:
2005
Bibliographic info:
Passive and Low Energy Cooling for the Built Environment, May 2005, Santorini Greece