Belok, J.
Year:
2005
Bibliographic info:
Dynastee 2005 Scientific Conference, 12-14 October, Athens, Greece

The purpose of this work was to determine U and g coefficients of the external wall with transparent insulation under real external climatic conditions. As the mainly methodology used for obtainment of the intended results was adoption of the methodology based on Paslink test cells system. To obtain from the collected data the searched coefficients various method of analysis was used.
As the last one has been used the software Lord, which author has obtained from the Paslink Organisation. In the paper are presented the models constructed using software Lord and final results of tests as coefficients U and g. This results are compared with results obtained previously.