Consideration of the air exchange between two rooms. Theoretische Betrachtung uber den Luftaustausch zwischen zwei Raumen.

Gives theoretical calculation of the amount of air which moves from one room to another due to a temperature difference between the two rooms. Suggests the possibility of reducing the heating or cooling load by allowing an overpressure in one of the two rooms.

Home ventilation rates : a literature survey.

Surveys published ventilation rates, primarily of single housing units. Finds helium is the most commonly used tracer gas and that average annual ventilation rate of most occupied houses is between O.5 and 1.5 air changes per. hour. Summarises important recommendations and gives bibliography of 230references.

Indoor air quality measurements in energy-efficient houses.

Reports field monitoring program by the Lawrence Berkeley Laboratory to assess the potential impact of reduced ventilation of indoor air quality. Three houses, designed to be energy-efficient, were monitored using a mobile laboratory. Parameters measured included infiltration rate, CO2, CO, NO2, NO, O3, SO2, HCNO, total aldehydes and particulates.

Application of thermography for evaluating the effectiveness of retrofit measures.

Reports the use of thermography for evaluating the effectiveness of a number of different retrofit measures carried out on single family dwellings in Twin Rivers. Discusses the use and limitations of thermography. Gives thermograms of parts of the houses before and after retrofit. Finds thermography is an effective tool for evaluating these retrofit measures which decreased the energy consumption by about 25%.

Measurement of wind loads on full-scale glasshouses.

Reports pressure measurements made on five shapes of glasshouses, under natural wind conditions and generally over a 90 deg. range of direction. Gives pressure coefficients from 48 tapping points for four different glasshouses.

The aerodynamic effects of windbreaks.

Suggests use of windbreaks to protect solar collectors and open air swimming pools and to protect buildings from the wind, thus contributing significantly to energy savings. Provides detailed knowledge concerning operation and effects of windbreaks: aerodynamic characteristics, effect of porosity of a windbreak on reduction of wind speed, effect of height and length, angle of incidence of the wind, effects of wind speed, ruggedness of the terrain and thermal stability of the atmosphere.

Design of a mobile laboratory for ventilation studies and indoor air pollution monitoring.

Describes a mobile laboratory designed for research and development studies of ventilation and energy utilisation in residential and commercial buildings. Describes the trailer and instrumentation chosen. Discusses factors considered in the design of the laboratory.

Improvements to existing buildings. Bygggtekniska mojligheter att spara energi i befintlig bebyggelse.

This is a practical handbook for retrofitting existing buildings. Describes with illustrations the addition of insulation, weatherstripping windows, and doors, addition of triple glazing and the installation of a vapour barrier. Discusses the savings for three different climate zones in Sweden.

The decontamination by air filtration of premises affected by formaldehyde. Sanering av lokaler kontaminerade med formaldehyd genom filtrering av luften.

Reports study to investigate the possibilities of purifying air from formaldehyde by using a filter that brings the air into contact with an adsorbent substance. Finds that the type of adsorbent substance that works satisfactorily is that which involves adsorption in combination with the oxidation breakdown of adsorbent substances. Compares costs for residential premises between a) an increase in ventilation and the use of a heat exchanger and b) the type of air purification and recirculation describes above.

Air leakage in dwellings. Luftlackage i bostader.

Reports investigation whose object was to devise a quick and simple method for checking the airtightness of a whole building. Describes pressurization of building and gives results from 20 single family houses and five multifamily buildings. Finds that the majority of the multifamily buildings investigated conform to requirements in the regulations and about one half of single family houses satisfy the requirements stipulated for the transitional period.