Airbase

AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

The AIVC website includes a protected content feature that provides access to AIRBASE. Access to the protected content is free of charge but requires you to register first.


 
The occupants' behaviour is one of the parameters which has the greatest influence on the air change in the dwelling. This applies both to naturally and to mechanically ventilated dwellings.
Kvisgaard B, Collet P F
A balanced ventilation system with heat recovery was designed and installed into an 11 storey prefabricated block building. Monitoring of the system operation was accomplished during a year.
Szalay Z
In this paper we approach the subject of ventilation and occupant behavior in multifamily buildings by asking three questions: 1) why and how do occupants interact with ventilation in an apartment building, 2) how does the physical environment (i.
Diamond R C, Modera M P, Feustel H E
In France, most of the ventilation systems in dwellings now consist of exhaust vents linked up with a fan, and air inlets.
Bienfait D, Moye Cl
The buildings built according to the latest construction technology aiming at energy saving are as tight as possible. The ventilation of a tight building has to be completely mechanical (supply and exhaust a i r system).
Laine J
A group of 18 identical well-insulated experimental houses in Sweden, utilizing a user controlled exhaust fan ventilation system, was monitored during 1985- 1986.
Blomsterberg A
SINTEF, The Foundation for Scienti f ic and Industrial Research at the Norwegian Institute of Technology, has monitored a number of experimental low-energy houses, and also undertaken measurements in some other houses to establish the energy consu
Granum H, Haugen T
Within the framework of the national research project "Ventilationin Housing Construction", studies on occupants ' ventilation behaviour were conducted in a demonstration building in Duisburg- Neumuhl (Federal Rep.
Erhorn E
This research attempts to offer partial answers as to how and why inhabitants of a rented apartment building behave as they do in aeration.
Hainard F, Rossel P, Trachsel C
One of the most important reasons for ventilation of dwellings is moisture control. Ventilation strategies differ.
Kronvall J
In order to save energy, i.e. ventilation heat losses, the fresh air change rate should be adapted to the prevailing need.
Fecker I, Wanner H U
Occupants can significantly influence both the heating energy requirements and the indoor air quality of a building by opening and closing doors and windows.
Kiel D E, Wilson D J
The need for reduced energy consumption has led to an overall decrease of air infiltration rates in buildings. particularly in dwellings. Unfortunately. this has given rise to a significant number of problems involving condensation.
Edwards R E, Irwin C
Each occupant in a room should be able to control his own indoor environment. Individual control can be achieved in many ways: from simple window-opening to automatically arranged personal mini-environment.
Railio J
Centrally controlled mechanical exhaust air ventilation systems in residential buildings can satisfactorily serve only a few of the inhabitants.
Holmberg R
A design process is developed for an OCCUPANCY RELATED VENTILATION CONTROL SYSTEM (ORVCS) in a new entertainment centre in Sha-tin, Hong Kong. The aim is to reduce the cost of space cooling.
Lee W L, Smith B E
20 low-income family houses were studied for Air Changes per Hour and Equivalent Leakage Area as measured by the Blower Door Test during the winter of 1985-86.
Kirkwood J J, Valentine D
The effects on ventilation behaviour of inhabitants in residential buildings have been investigated as a part within several years' German R and Dprogramme.
Trepte L
Recent work by the National Radiological Protection Board indicates that higher than average levels of exposure due to radon occur in the South West.
Penman J M
A study was made of one hundred subjects who were exposed to air flow with a turbulence as occuring in typically ventilated spaces. Turbulent air flow is seen as more uncomfortable than laminar flow.
Fanger P O, Christensen N K

Pages