Airbase

AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

Keynote speech describes the difficulties of designing air conditioning system with human comfort in mind. Lists design fundamentals for satisfactory indoor air quality, together with a description of some case studies.
Sandelewski A
With respect to architecture and building materials, this reorientation process has led to advanced technological developments designed to achieve a reduction in the consumption of resources for heating purposes.
Seyer R, Trepte L
Sustained efforts to conserve energy during the last 15 years have taken place at the expense of the indoor environmental quality. Ventilation air volume has been reduced to a minimum.
Flatheim G
Management for acceptable indoor air quality in office buildings requires that the buildings are properly designed, operated and maintained, and that property managers have the knowledge necessary to respond to changes in building operation and us
Shaw C Y, Vaculik F, Patton D W, Comeau G M
The functional and technical requirements which have been set for ventilation systems in dwelling houses of the future will result in ventilation systems featuring trouble-free and demand-controlled operation.
Kohonen R
In an experimental facility, we studied the performance of a task ventilation system designed for use in office buildings.
Fisk W J, Faulkner D, Bauman F S, Arens E A
This paper describes tests of thermal and ventilation performance of two relatively new occupant-controlled localized thermal distribution (also called task ventilation) systems.
Arens E A, Bauman F S, Johnston L P, Zhang H
The use of computers for data acquisition and analysis in air exchange measurements with tracer gases has become state of the art for the researcher.
Rabenstein R, Heidt F D
In the framework of a CEC-DGXVII demonstration project a hygroregulating natural ventilation system is being evaluated in 52 occupied apartments.
Wouters P, Vandaele L
This paper describes the activity on Air Infiltration and Ventilation of the research group of "Dipartimento di Energetica" in Politecnico of Turin.
Borchiellini R, Cali M
This paper discusses three methods for measuring interzonal air movements in two zone buildings: 1. initial injection of one tracer into a single room, 2. repeated injection of one tracer in two rooms, 3.
Heidt F D, Rabenstein R, Schepers G
This paper describes the use of tracer-gas techniques to measure airflow in a rectangular duct and a HVAC system.
Riffat S B, Holmes M
Ventilation efficiency may be defined as the capability of a given ventilation system to achieve the best balance between indoor air quality and energy conservation requirements:
Bienfait D
This paper treats the structure of models for predicting interzonal airflow and contaminant dispersal in buildings.
Grot R A, Axley J A
An appropriate way to identify the most efficient ventilation systems and improve their design is to use design codes for ventilation rates.
Riberon J, Bienfait D, Barnaud G, Villain J
This paper presents some of the early theoretical work conducted within the framework of a research program aimed at analysing the interaction between gas-fired domestic appliances and the indoor environment in terms of energy consumption, indoor
Fracastoro G V, Masoero M, Mazza E
An investigation has been carried out using computational fluid dynamics methods to study the performance of an air curtain at the door of a heated building.
Lam J K W, Ruddick K G, Whittle G E
A new European norm for measuring the heat transfer rate of radiators is under discussion [ CEN TC 130 ]. This testing can be done either in a closed chamber with cooled walls or in a open chamber with a controlled air supply.
Huber A, Moser A, Chen Q
A new facility for the study of ventilation in buildings has been recently developed at the University of Basilicata (Potenza, Italy).
Fracastoro G V, Nino E, Coretti G
As part of the IEA Research Program Annex 18 "Demand Controlled Ventilation Systems" various ventilation systems were examined in a test room. During research, in addition to thermal comfort issues, removal of particles was of importance.
Schwab R, Mayer E

Pages