This paper presents a new simplified method to measure the air entrainment ratio of an active chilled beam or induction unit.
Volume 7: 2008-2009
International Journal of Ventilation, Volume 7, 2008-2009
Volume content
A Numerical and Experimental Evaluation of a Natural Wind Driven Suction Cylinder for Building Ventilation | 2008 | English
The suction cylinder described in this paper is a device to increase the ventilation flow rate, especially in naturally ventilated buildings. Outdoor wind is the driving force.
A Paradigm Shift to Ensure Proper Ventilation and Better IAQ - The Energy Savings and Cost Benefits of a Dedicated Outdoor Air Approach | 2008 | English
An energy and cost analysis has been performed which compared a dedicated outdoor air system (DOAS) with chilled radiant cooling panel (CRCP), designed for an official building located in the hot and humid climate of Chennai, India, and an existin
A formulation to analyze ventilation duct system airflows employing, as the basic unknowns, the flow rates in the channel sections and the static pressures at the channel section ends is presented.
In this study, the measured and predicted air distribution of an active chilled beam in a typical office room is described.
An Experimental Analysis of the Two-Zone Airflow Pattern Formed in a Room with Displacement Ventilation | 2008 | English
This paper presents the results of tests on the two-zone airflow pattern that forms in a room with displacement ventilation under conditions of various heat sources and airflow rates.
The present work contains the details of an investigation of air diffusion and comfort issues of an isolation room of a hospital. Two types of cases have been chosen for a unidirectional ventilation system of the isolation room i.e.
Comparison between Numerical and Observed Air and Contaminant Distribution for Mechanical Mixing and Displacement Ventilation Coupled with a Local Exhaust - Lessons Learnt | 2008 | English
CFD modelling can be used in the design of ventilation systems. However, simplifications in room airflow models may lead to errors and discrepancies between predictions and reality.
Development of Effective Ventilation System for Electric Multiple Unit (EMU) Train for Mumbai Suburban Railway | 2009 | English
In the Island city of Mumbai, the Suburban Railway System operates 2500 EMU trains each of 9 or 12 cars and 6.3 millions passengers commute per day. It is considered to be the lifeline of the city.
Desiccant cooling is a potentially environmentally friendly technology which can be used to cool buildings without the use of traditional refrigerants. We have studied the operation of a desiccant cooling system in France.
Effects of Intermittent Air Velocity on Thermal and Draught Perception during Transient Temperature Conditions | 2008 | English
Previous research has shown that air movement has a significant influence on humans’ thermal comfort.
Estimation of the Effectiveness of Cross Ventilation as a Passive Cooling Method for Houses | 2008 | English
The effectiveness of various methods for saving energy and improving the indoor environment in buildings depends upon the building conditions under which those methods are applied.
Evaluation of Local Thermal Discomfort in a Classroom Equipped with Cross Flow Ventilation | 2008 | English
This paper presents an evaluation of the local thermal discomfort level in a classroom equipped with cross ventilation, for a typical moderate summer day in Portugal.
The capability of HVAC systems is of interest when contracting specific function criteria such as room temperature. The probability of maintaining the criteria reflects the risk the building contractor will take when giving guarantees.
Horizontal Air-to-Earth Heat Exchangers in Northern Italy - Testing, Design, and Monitoring | 2008 | English
Earth heat exchange (EHX) through buried horizontal air ducts (EHXair-hor) can be an effective passive/hybrid system to reduce heating and cooling loads in temperate climate zones.
Integrating Active Thermal Mass Strategies with HVAC Systems: Dynamic Thermal Modelling | 2009 | English
Active thermal mass strategies can be used to enhance the performance of thermal mass through integration with the heating, ventilation and air conditioning (HVAC) systems.
This paper addresses the applicability of passive and low energy cooling technologies in the Czech Republic.
It is difficult to design a naturally ventilated indoor environment because there is insufficient knowledge to evaluate the effect of the natural ventilation space quantitatively. Especially, natural ventilation rate is not yet fully understood.
Age-of-air is a technique for evaluating ventilation that has been actively used for over 20 years.
Numerical and Experimental Study of an Airing Device for Controlled Natural Ventilation of a Building | 2008 | English
The rationale of an advanced natural ventilation system should be to control airflows and air temperature during winter, and to avoid unnecessary energy losses and local draught, while maintaining an adequate ventilation rate.