Compares methods of calculating ventilation rates in mechanically ventilated animal houses. Ventilation rates in several occupied animal houses were found by 1) measurement of internal to external temperature and moisture differences using a psychrometer;2) measuring decay rates of radioactive krypton as a tracer gas;3) estimating from manufactures rating of fans. Concludes that different methods agree to within the order of 5 or 10% and suggests the use of psychrometer techniques for simplicity.
Describes measurements of air change rates using radioactive krypton as a tracer gas in a domestic house. Reports measurement of air change rates for a single room heated by either an open fire or a central heating radiator. Examines effect of opening doors and windows and rate of flow up chimney. Found with all the doors open very large airflows from heated downstairs roomsto unheated upper storey, causing large heat transfer to bedrooms: if bedroom doors were shut very little warming of bedrooms took place.