Assessment of Wind Impact on Building Air Leakage Measurements using a Model Scale Experiment

Nowadays, many countries include requirements for building airtightness in their current national regulations or energy-efficiency programs, mainly for concern about reducing building energy consumption due to air leakage. Moreover, some countries impose a mandatory justification with an air leakage measurement. Therefore, the uncertainty of the measurement results has become a key concern in several countries over the past year. More specifically, the influence of wind speed has been identified as one of the major sources of error on the measurement result.

Recordings from the AIVC & TightVent Webinar: Impact of wind on airtightness test

The recordings and the slides of the recent AIVC & TightVent Webinar "Impact of wind on airtightness test" are now available online at: https://www.aivc.org/event/8-november-2021-webinar-impact-wind-airtightness-test-results

The full collection of past events’ recordings and slides can be found at: https://www.aivc.org/events/webinars

English

8 November 2021 – Upcoming Webinar "Impact of wind on airtightness test results"

The Air Infiltration and Ventilation Centre and TightVent Europe are organizing the webinar "Impact of wind on airtightness test results" to be held on November 8th, 2021 at 15:30-16:45 CET. This webinar aims at presenting AIVC's Ventilation Information Paper on the impact of wind on airtightness test results and at presenting results of field measurements to better estimate and reduce the impact of wind fluctuations on airti

English

VIP 41: Impact of wind on the airtightness test results

Building airtightness tests have become very common in several countries, either to comply with minimum requirements of regulations or programmes, or to justify input values in calculation methods. With more widespread use it has become increasingly important to understand and quantify the reliability of these tests.

Insights into the impact of wind on the Pulse airtightness test in a UK dwelling

Requirements for measuring the building airtightness have been proposed and included by many countries for national regulations or energy-efficient programs to address the negative effect of poor airtightness on building energy performance, durability and indoor environment. The methods for measuring building airtightness have continuously improved and evolved over a number of years.

Designing a model-scale experiment to evaluate the impact of steady wind on building air leakage measurements

Since the 1970s, many authors have discussed the impact of poor airtightness on building energy use, indoor air quality, building damage, or noise transmission. Nowadays, because poor airtightness affects significantly the energy performance of buildings, and even more significantly with low-energy targets, many countries include requirements for building airtightness in their national regulations or energy-efficiency programs. Building pressurization tests are increasingly used for compliance checks to energy performance requirements and may result in severe penalties.

Wind speed in building airtightness test protocols: a review

Since the 1970s, many authors have discussed the impact of poor airtightness on building energy use, indoor air quality, building damage, or noise transmission (Carrié and Rosenthal, 2008) (Tamura, 1975) (Sherman and Chan, 2006) (Orr and Figley, 1980). Nowadays, because poor airtightness affects significantly the energy performance of buildings, and even more significantly with low-energy targets, many countries include requirements for building airtightness in their national regulations or energy-efficiency programs.