Submitted by Maria.Kapsalaki on Tue, 06/27/2023 - 12:14
This paper describes the ongoing development of a new tracer gas test (TGT) for total air change rates measurement. This new TGT, intended for use in large-scale IAQ assessments and based on constant tracer injection, employs an alternative tracer gas that is more adequate than the currently employed SF6 and perfluorocarbons and that can be co-captured and co-analyzed along with commonly assessed VOCs using a commercial passive IAQ sampler. Via literature study and lab testing, decane-D22 was found to be a suitable tracer substance.