Hitoshi Takeda and Yasunao Iriguchi
Year:
1999
Bibliographic info:
Building Simulation, 6, 1999, Kyoto, Japan, p. 99-104

The LESCOM program using the Response Factor Method developed by the authors was applied to the direct gain system and calculation of fluctuations in room temperature. Regarding the solar water collector, the efficiency straight line was obtained from the measured values. The one-dimensional thermal stratification was applied to the water storage tank. It was discovered from the measured values that relations between the amount of solar radiation on the solar cells and the amount of power generation in photovoltaic power generation could be formulated in the linear equation. In conclusion, simulation programs for typical systems of the ecological house were drawn up and verified. The accuracy of the simulation programs was found to be comparatively high.