Study on the estimate of the air conditioning control systems in large dome.

In the large space, for example in large-dome, the space is often divided into some zones without partition walls for air conditioning. In this case the following are problematic, The first problem is that it is difficult to control the temperature of the target zone considering the influence by the supply air temperature in the adjacent zone for air conditioning. The second problem is that it is difficult to set the temperature sensor for air conditioning control at the location in which the temperature means the average temperature in the target zone.

Does smell spell success?

A Japanese company is claiming huge increases in productivity since introducing artificial srriells into the workplace, and more retailers are using odours to try and influence buying decisions. Ewen Rose asks if smells circulated by the air conditioning system can really help us to work harder and better.

Phase-change wallboard and mechanical night ventilation in commercial buildings: potential for HVAC system downsizing.

As thermal storage media, phase-change materials (PCMs) such as paraffin1 eutectic salts; etc. offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. By embedding PCMs in gypsum board, plaster, or other wall -covering materials, the building structure acquires latent storage properties. Structural elements containing PCMs can store large amounts of energy while maintaining the indoor temperature within a relatively narrow range.

The use of multipoint monitoring as a tool for commissioning buildings for IAQ.

One basic goal of the commissioning process is to make sure that the HVA C system is functioning as intended. In particular, it is intended that the HVAC system not only provide adequate ventilation for the building occupants but also achieve adequate pressurization of the occupied spaces to prevent the infiltration of unconditioned air. One technique for evaluating the performance of the HVAC system in these areas is to use continual, multipoint monitoring of carbon dioxide, carbon monoxide, and dew point at selected locations in the building and the HVAC system.

Numerical simulation of the air conditioning environment in a computer room.

This paper describes the development of software for simulating the air-conditioning environment in a computer room. This software uses a finite volume method combined with a rectangular structured mesh system and a k-£ two-equation model for turbulence. Some special modeling techniques are also used. This software has two purposes: (1) to optimize the layout of a computer room, thus minimizing the electric power used for air conditioning, and (2) to reproduce the situation in which an accident is caused by an air-conditioning problem and to assist in an investigation of the problem.

Bioclimatic design strategies in temperate climate. Consistency of passive cooling and heating.

In the temperate climate, the consistency of bioclimatic designs for heating and cooling is essential. However, the traditional Japanese houses which have excellent cooling techniques often disclose their poor thermal performance in the winter time. Since Jong it has been said that they sacrificed the heating performance in return for the cooling performance, as a result of their choice in the time when the consistency was technically impossible.