The use of passive solar gains for the pre-heating of ventilation air in houses.

The introduction describes the principle of SVP (Solar Ventilation Pre-heating) and then reviews a number of current related topics. Heat recovery is considered. Work on other devices which produce solar heated air is reviewed. The main driving forces of natural ventilation are wind pressure and thermal buoyancy. One of the problems is that the magnitude of these forces is very variable. The basis of SVP demands a thorough knowledge of airflow through buildings.

An evaluation of the effectiveness of air leakage sealing.

A field study was carried out to evaluate the effectiveness of air leakage sealing techniques for reducing air infiltration in houses. Presealing and postsealing air leakage tests were performed upon 82 single detached houses inWinnipeg or southern Manitoba. All houses were placed under a negative pressure, and leakage sites were identified using smoke pencils. Windows and doors were weather-stripped and other unintentional openings caulked and sealed using specified materials and techniques.

Demonstration of air leakage reduction program in Navy family housing.

The Department of Defense has an ongoing program to conserve energy at its installations. One method of energy conservation in residential units is the reduction of excessive air leakage by appropriate retrofits. Under the sponsorship of the Office of Navy Family Housing, a demonstration of air leakage reduction was undertaken at the Great Lakes Naval Training Center. Twoprocedural documents were prepared in draft form: a manual for use by supervision and a handbook for the on-base mechanics doingthe air leakage retrofits.

Pressurization testing of federal buildings.

Seven federal buildings ranging in size from 1900 to 48000 m2 of floor area were pressure tested to determine the airtightness of the building envelopes. These tests are part of a larger project to evaluate the thermal integrity of the envelopes of federal buildings. The buildings were pressurized using the air-handling equipment in the buildings and a constant-injection, tracer gas technique to measure the airflow through the fans. In addition, selected windows in some of these buildings were pressure tested separately to determine the airtightness of individual components.

Measurements of air infiltration and airtightness in passive solar homes.

The airtightness of 82 passive solar homes located throughout the United States was studied using tracer gas measurements of air infiltration and pressurization testing. The air infiltration measurements employed the tracer gas decay technique in a low-cost mode employing air sample bags and off-site infiltration determination. The infiltration rates measured under natural conditions ranged from about 0.05 to almost 2 air changes per hour (ACH). The pressurization test results ranged from 1 to more than 30 ACH at 50 Pa, with an average of about 10 ACH.

Air leakage and fan pressurization measurements in selected naval housing.

Data from detailed tracer concentration decay and induced pressurization measurements were obtained in tests of duplex and row apartments at Norfolk, Virginia and Pensacola, Florida to accurately determine air leakage characteristics of selec

Air leakage at service penetrations in ceilings. Luftlekkasjer ved gjennomforinger i tak.

Work has been in progress for several years on the revision of Byggeforeskrifter (Norwegian Building Regulations), and the new chapter 54 sets quantitative requirements for the air tightness of sections of a building and the building as a whole. In this project, good and bad solutions are illustrated and an effort is made to show the importance of good workmanship. The commonest types of leakage were identified by examination of Leca pipes.The conclusion drawn from the investigations was that Leca pipes should be surface treated to prevent large air leakages.

Indoor air quality measurements in an air-conditioned office building.

Air qulaity measurements along with airflow rate measurements of air conditioning system were conducted in an office building occupied by workers with clerical activities. Contaminamts measured were CO2, SPM (suspended particulate matters) NOx and airborne bacteria. Indoor CO2 and SPM levels were found to be quite high, 1,600 ppm (CO2) and 0.25mg/ m3 (SPM), respectively, at their maximum and exceeded Japanese Standards The cause of the high concentration was found to be air leakage in the outdoor air intake duct. The air leakage rate was estimated applying mass-balance model of CO2.

Measured air leakage of buildings.

The session on measured air infiltration rates in residences showed that the situation has changed drastically since the first symposium on air infiltration in 1978. Whereas in 1978 little measured data or pressurization data, or both, exist. This session contained excellent papers that summarised the state of the existing data on air infiltration.

Airtightness and thermal insulation: building design solutions.

Approximately 40% of the energy consumption in Sweden is utilized in the heating of buildings. In order to reduce the amount of energy utilized for heating purposes, more stringent thermal insulation requirements for buildings were introduced.