Air-to-air heat exchangers for energy efficient ventilation of "tight" structures.

Reducing the air change rate of a house increases the concentration of pollutants in the indoor air. These pollutants are identified and located within the residential structure. Air-to-air heat exchangers are suggested tocontrol ventilation, and the three basic types described.

Continuous monitoring in occupied residences of air contaminants from unvented combustion sources

Continuous monitoring of NO, NO2, CO, CO2, and O2 depletion was conducted in 14 residences (13 with kerosene space heaters and one without) in two locations in the residence (room with the heater and bedroom) and outdoors. The continuous monitor

Characterization of residential air pollution from unvented kerosene heaters

Investigates the generation of pollutants from unvented convective and radiant kerosene heaters in a residence over a 3 month period. The measured concentrations of carbon monoxide were low. However, under the conditions of use which were studied concentrations of SO2, NO, NO2, and CO2 reached or exceeded levels recommended for indoor air. Further, it was demonstrated that using a semi-open door to provide ventilation did not reduce concentrations of pollutants to acceptable levels.

Sampling and monitoring toxic gases in indoor environments

A discussion of different approaches to indoor air pollutant monitoring is presented. Indoor sampler design criteria are outlined. Grab samplers, personal samplers, passive and single-use devices, and in-situ measurement instruments are compared to novel, syringe/adsorbent tube samplers. These instruments provide automated, sequential, time-averaged collection of avariety of indoor pollutants, including hydrocarbon/halocarbon organic vapours, CO, CO2, HCOH, tobacco smoke, combustion and odorous mixtures, and particulate matter. In addition, the samplers can be used in infiltration studies.

A systems approach to the monitoring of indoor air pollutants

Building design and building construction technology has improved in the past decade and the concern over indoor air pollutants and their health effects has increased. A multi-point, multi-pollutant air sampling and analysis network was insta

IEA Annex IX 'Minimum Ventilation Rates' - Survey and Outlook.

Eleven countries are cooperating to establish guidelines for minimum ventilation rates which are sufficiently large to meet the demand for outdoor air in buildings without unnecessarily wasting energy. The most important pollutants have been identified as: carbon dioxide, tobacco smoke, formaldehyde, radon, moisture, body odour, organic vapours and gases, combustion products and particulates. To a certain degree some of thesesubstances can be used as indicators for acceptable air quality to establish minimum ventilation rates.

Development of occupancy-related ventilation control for Brunel University Library.

A microprocessor system is being developed for occupancy related ventilation control of mechanical ventilation in Brunel University Library. The objective is to reduce space heating costs by decreasing the input of (cold) fresh air to the building below existing (heating season) levels, when the number of occupants in the building is sufficiently small to allow this. The occupancy levels can be measured in terms of CO2 level in the exhaust duct. The microprocessor control system is operational when linked to a CO2 monitor.

Minimum ventilation rate. A research report.

An investigation of the minimum fresh air supply per person required to prevent the occurrence of unacceptably offensive odour due to stale air in offices and similar buildings. The study was made under everyday conditions as far as possible, in different buildings, various size rooms, different densities of occupancy, with men or men and women, and with mechanical or natural ventilation.

The IEA project on minimum ventilation rates. IEA-Projekt 'Minimale Luftungsraten'

The minimum fresh air requirements needed for perfect indoor air quality are being studied and these will form the basis of the Swiss Guidelines for Ventilation. An optimization between the need to reduce heat loss and fresh air requirements for health is the aim. Pollutants in indoor air, such as formaldehydes, radon, carbon dioxide, tobacco smoke, carbon monoxide, nitrogen dioxide and particulates, have to be considered.

Multivariate model for predicting NO2 levels in residences based upon sources and source use

Diffusion-type passive monitors were placed for a two-week period in each of 303 residences in the New Haven (Conn.) area during a 12 week sampling period January to April 1983. For each home NO2 levels were recorded outdoors, and in three ro