Discusses insulation of lofts, roofs, walls, windows and floors, natural ventilation of dwellings and mechanical ventilation with heat recovery in dwellings. Considers cost benefits of weatherstripping and constant-flow ventilators for naturally ventilated houses. Concludes that installation of mechanical ventilation with heat recovery is uneconomic, but adding a heatexchanger to an existing mechanical ventilation system has economic benefits.
Presents the extra costs in new housing of a number of measures designed to reduce space heating costs. The measures used to reduce energy consumption in new houses in Sakatoon were:< 1. airtightness with controlled ventilation< 2. superinsulation< 3. use of the south windows for passive solar gain.< States that results are applicable in most parts of the Canadian prairie.
Until recently, natural ventilation was adequate for the indoor air environment of buildings. Today, with added insulation and tighter building envelope standards, indoor air quality is more dependent on mechanical means. The conventional and new control strategies for indoor environments are reviewed, and the point is made that good indoor air quality is attainable with cost effective means if the proper constraints are maintained. To improve control strategies, several suggestions are made:< 1.
Notes that as houses become tighter, adventitious ventilation decreases. Discusses attitudes to varying degrees of tightness. Explains introduction of the supply exhaust system which comprises air supply, air exhaust and heat recovery. Notes requirements for economic use of the system and relates installation costs to potential savings. Tabulates systems currently available in Sweden(December 1980)noting maximum air flow, position of heat exchanger and other factors.
This research report explores the possibilities for energy saving in municipal office buildings. It is based on a study carried out for one London borough in mid-1980`s taking one specific building complex, comprising two adjoining buildings, as an example. The energy-saving measures covered include reduction of air-change rates by draught- proofing windows doors and skylights, and the report indicates the scale of potential savings along with the capital costs.
Gives results of a statistical survey of energy consumption in British government buildings. Suggests one reason for high consumption may be excessive ventilation. Reports field trial of the effect of reducing natural ventilation in a London office building. Window frames were sealed with a rubber mastic, giving an annual fuel saving of 22%. Finds measure was highly cost effective with a payback period of less than three years.< Discusses problem of heat loss through large doors in hangars and workshops.