Predicted and measured air change rates in houses with predictions of occupant IAQ comfort.

The purpose of this study was to test an Indoor Air Quality model on a variety of Canadian homes, and use this model to determine the optimal ventilation levels necessary to provide appropriate comfort levels. The Indoor Air Quality model tested (the AQ1 program), was a single zone hour-by-hour model of air leakage, mechanical ventilation and pollutant concentration. Measured weekly air change rates were compared to the model's predicted rates, and sensitivity analysis' performed on a number of inputs.

CONTAM93 User manual.

Application of a multi-zone airflow and contaminant dispersal model to indoor air quality control in residential buildings.

A new multizone airflow and contaminant dispersal model CONTAM93 is described, along with a demonstration of its application in a study of ventilation and contaminant control in single-family residential buildings. While CONTAM93 is based on existing theory of network airflow analysis and contaminant dispersal, the model employs a unique graphic interface for data input and display. The interface uses a sketchpad to describe the connections between zones and icons to represent zones, openings, ventilation system components, and contaminant sources and sinks.

Ventilation concept, indoor air quality and measurement results in the "Passivhaus Kranichstein".

The "Passivhaus Darmstadt-Kranichstein" is a 4 unit terrace house with an extremely low total annual energy consumption of less than 32 kWh/m² of living area, thereof about 12 kWh are needed for room heating /Feist 1994/. The determinig factors for the low consumption are the superinsulation, airtightness of the thermal envelope in combination with a highly efficient VAV ventilation system, and an improved window construction. The "Passivhaus" therfore is a typical example of an improved low energy house.

The role of infiltration for indoor air quality

Multifamily buildings with natural ventilation are still being built and exploited. Such buildings are often equipped with individual gas-fired water heaters located in windowless bathrooms. It implicates the possibilities of improper gas exhaust as a result of the decrease of infiltration, what could be sometimes even harmful for the occupants' health. Based on the numerical simulations, analysis of ventilating air flows in typicalmultifamily dwelling house will be carried out.

Numerical assessment of thermal comfort and air quality in an office with displacement ventilation.

Computational fluid dynamics has been used for assessing the thermal comfort and air quality in an office ventilated with a displacement system for a range of supply air conditions. Thermal comfort is predicted by incorporating Fanger's comfort equations in the airflow model. Indoor air quality is assessed according to the predicted contaminant concentration and local mean age of air. The performance of the displacement ventilation system is then evaluated based on the predicted thermal comfort and indoor air quality.