Natural ventilation for crown court: developing statistical assessment techniques at the design stage.

The ventilation performance of a proposed naturally-ventilated court-room was predicted and assessed on a statistical basis with regard to the local meteorological conditions. Summertime ventilation was to be provided via an underfloor duct and controllable vents at roof levels, under the action of wind and buoyancy forces. Wind pressure coefficients expected on the external facade of the building were obtained from wind tunnel measurements on a scale model.

The influence of a controlled natural ventilation on the indoor radon decay products concentration: a case study.

Air exchange rates in occupied buildings are difficult to assess due to their dependence on a multitude of climatic parameters and inhabitant behaviour. Moreover, the assessment of the influence of the air exchange rate on the radon progeny concentration is hampered by the diurnal and seasonal fluctuations of the indoor radon levels.