Field survey of indoor air pollution in residences with suspected combustion related sources

Thirty residences were monitored for nitrogen dioxide, carbon monoxide, formaldehyde, respirable suspended particles, and air exchange rate for forty-one one-week periods using integrating samplers. The residences were located in the northwest a

Continuous monitoring in occupied residences of air contaminants from unvented combustion sources

Continuous monitoring of NO, NO2, CO, CO2, and O2 depletion was conducted in 14 residences (13 with kerosene space heaters and one without) in two locations in the residence (room with the heater and bedroom) and outdoors. The continuous monitor

Characterization of residential air pollution from unvented kerosene heaters

Investigates the generation of pollutants from unvented convective and radiant kerosene heaters in a residence over a 3 month period. The measured concentrations of carbon monoxide were low. However, under the conditions of use which were studied concentrations of SO2, NO, NO2, and CO2 reached or exceeded levels recommended for indoor air. Further, it was demonstrated that using a semi-open door to provide ventilation did not reduce concentrations of pollutants to acceptable levels.

Sampling and monitoring toxic gases in indoor environments

A discussion of different approaches to indoor air pollutant monitoring is presented. Indoor sampler design criteria are outlined. Grab samplers, personal samplers, passive and single-use devices, and in-situ measurement instruments are compared to novel, syringe/adsorbent tube samplers. These instruments provide automated, sequential, time-averaged collection of avariety of indoor pollutants, including hydrocarbon/halocarbon organic vapours, CO, CO2, HCOH, tobacco smoke, combustion and odorous mixtures, and particulate matter. In addition, the samplers can be used in infiltration studies.

An investigation of operational factors that influence emission rates from gas appliances

Reports the result of investigation of the impact of various operational factors on trace combustion products emission rates from unvented gas appliances including ranges and space heaters. The impact of the following factors on the indoor NO, NO2 and CO emission rates were evaluated under controlled conditions in an environmental chamber - 1) the appliance typeand/or design, 2) the primary aeration level, 3) the fuel input rate, 4) the time dependence of emission rates, and 5) the presence of absorbing surfaces such as wood, plaster board, curtains, carpets, linoleum and plaster.

A systems approach to the monitoring of indoor air pollutants

Building design and building construction technology has improved in the past decade and the concern over indoor air pollutants and their health effects has increased. A multi-point, multi-pollutant air sampling and analysis network was insta

Characterization of particulate and organic emissions from major indoor sources

As our understanding of human exposure to air pollutants improves, it is becoming increasingly evident that indoor environments play a critical role in determining exposures. However, it is not possible at the present time toestablish the relative contribution of indoor and outdoor sources to personal exposures, nor can the contribution of specific indoor emissions be quantified. To address these issues, a chamber experiment was initiated to measure particulate and organic emissions from important indoor sources.

A pilot study to obtain 24-hour air pollution exposure profiles

A pilot study was conducted using workers from a semiconductor plant. Describes the methods used to acquire and evaluate air pollution exposure data for significant environments (including workplace, in-transit, and residence) to which workers are exposed throughout a typical 24-hour day. Summer andwinter measurements were made on products of combustion, radon, respirable particulates, and a variety of organic compounds including methylene chloride.

Equipment for personal and portable air monitoring - A state-of-the-art survey and review

The Harvard School of Public Health and the Energy and Environmental Policy Centre of the Kennedy School of Government, under the auspices of the Electric Power Research Institute and the Gas Research Institute, conducted a"Workshop on Evalu

A standard for minimum ventilation.

The air infiltration associated with ventilation in buildings is recognized in ASHRAE Standard 62-1981, Ventilation for Acceptable Indoor Air Quality. In the light of recent trends toward increasingly tight housing, which limits air infiltration for ventilation, dependence on this source of outside air is onepoint that must be carefully considered in the Revised Standard. Other points to be considered are ventilation efficiency, necessary dilution of particulates and other pollutants, and how changes in humidity, air temperature and local heating may alter pollution levels in buildings.