Smoke control in VA hospitals.

Smoke control makes use of mechanical fans to produce airflows and pressure differences to control smoke movement. Describes one day of tests of the smoke control systems at the 6-storey VA hospital, San Diego, California. 

Indoor air quality: is my home healthy for me?

Gives basic facts about indoor air pollution for homeowners. Lists common indoor air pollutants and guidelines for generally acceptable levels of selected air contaminants. Some suppliers of measurement equipment are mentioned.

Personal exposure to respirable particles: a case study in Waterbury, Vermont.

A study to assess personal exposure to respirable particles was conducted during January to March 1982 in Waterbury, Vermont. 48 non-smoking volunteers carried Harvard/EPRI personal samplers every other day for two weeks. 

Effects of residential wood combustion on indoor air quality: a case study in Waterbury, Vermont.

An indoor/outdoor monitoring study was conducted during January to March 1982 in Waterbury, Vermont. Respirable particle measurements were made inside and outside 24 homes (all occupants were nonsmokers), 19 with wood-burning appliances and 5 without. Data were also obtained on seasonal air exchange rate, heating fuel consumption, and relevant home characteristics. Findings indicate that indoor particle levels are consistently higher than outdoor values regardless of heating fuel type.

Air-to-air heat exchangers for energy efficient ventilation of "tight" structures.

Reducing the air change rate of a house increases the concentration of pollutants in the indoor air. These pollutants are identified and located within the residential structure. Air-to-air heat exchangers are suggested tocontrol ventilation, and the three basic types described.

Field survey of indoor air pollution in residences with suspected combustion related sources

Thirty residences were monitored for nitrogen dioxide, carbon monoxide, formaldehyde, respirable suspended particles, and air exchange rate for forty-one one-week periods using integrating samplers. The residences were located in the northwest a

Ventilation with open windows.

The ventilation rate and energy consumption of one of the ECRC test houses was monitored continuously during one heating season, with one bedroom window open by various amounts. Results show that a very small window opening is sufficient to satisfy ventilation requirements most of the time. 

The computer simulation of smoke movement during building fires.

Gives brief description of the new computer package developed by the Oscar Faber partnership for predicting the movement of smoke during a building fire. The model treats the building as a network and calculates air flow between rooms driven by stack effect and wind pressure. Four levels of complexity in the simulation are possible. Describes the results of these different types of analysis for a multi-storey building.

Measurement and calculation of the ventilation through a vertical sash-window without wind. Messungen und Berechnungen uber Stossluftung durch vertikal Schiebefenster bei Windstille.

Reports measurements of the natural ventilation through a vertical sash-window in calm weather. Describes test window and room. Gives theoretical expression for the ventilation depending on the amount the window is open, inside to outside temperature difference and the difference in height of the openings. Reports two tests of ventilation rate made using smoke. Concludes that a vertical sash window gives very good ventilation even without wind. Finds that tests corraborated the formula which would also apply to a deeper room.

Air leakage testing.

The significance of air tightness on building performance and the factors affecting the air leakage performance of the building enclosure are discussed. the ability of the ASTM standard air leakage test method to check the quality of design and manufacture of factory-assembled walls, windows and doors as well as the inability of the method to provide the building designer with quantitative air leakage data for calculating heating and cooling loads and designing smoke control means is also discussed.