Sasaki J.R..
Year:
1973
Bibliographic info:
Spec. Ass. vol.15 no.5 p 15-18.= N.R.R.C. Division of Building Research technical paper no.407

The significance of air tightness on building performance and the factors affecting the air leakage performance of the building enclosure are discussed. the ability of the ASTM standard air leakage test method to check the quality of design and manufacture of factory-assembled walls, windows and doors as well as the inability of the method to provide the building designer with quantitative air leakage data for calculating heating and cooling loads and designing smoke control means is also discussed. For the latter purpose, leakage values obtained from air leakage studies on completed buildings are recommended.