Optimizing Building Performance by Integrating Experiential Thermal Comfort in Students’ Accommodation

In the absence of thermal comfort standards in India, architects and designers have no choice, except to provide air conditioning to meet thermal comfort criteria for achieving green building rating for their projects and thus end up using more energy eventually. Significant Energy saving can be brought about by promoting naturally ventilated buildings as thermally comfortable building by retrofitting them with energy conserving measures for improving thermal performance.

Improving Increased Thermal Capacitance As A Passive Energy Management System with Underground Piping

This paper evaluates the influence of underground piping on the performance of using increased thermal capacitance (ITC) as a passive energy management system on an office building. The building’s cooling load will be decreased by circulating water from a storage tank through underground piping then through a piping system located in the building’s ceiling. The cooling load of an ITC enhanced building with underground piping is compared to the cooling load of an ITC enhanced building without underground piping and a reference building without ITC at all.

Simulation of Indoor Environment in the Concert Hall Housed in A Converted Former Church

The paper presents an application of a new method to simplify models of heat sources in CFD simulations of large spaces exposed to variable occupancy patterns. The previously developed approach is applied in a real scenario of a recently refurbished former church built in 14th century, now used as a concert and conference hall with up to 350 visitors staying for different period during each day.

Naturally Ventilated Building Design Under Uncertainty using Design of Experiments

Appropriate building design for natural ventilation can reduce discomfort, while saving energy on airconditioning. Parametric building simulation analysis for natural ventilation typically consists of several design variables and input parameters with uncertainty, making it computationally intensive. For optimizing the building design within a reasonable timeframe, design of experiment techniques based methodology is proposed. Firstly, the significant design variables and input parameters are identified.

Limitations of Building Performance Simulation: Modelling A Building with Gabion Walls

Simulations were conducted to optimize the design of a small building with walls constructed of limestonefilled gabion baskets. Different methods of insulating and weatherproofing the gabion walls were compared, with the indoor operative temperatures in the summer design week providing the critical comparison. The performance of the gabion building was compared with that of more conventional construction types to demonstrate the superior thermal performance of gabions in a temperate climate (Australia). This paper also addresses an issue with simulating gabion walls.

Measured Internal Temperatures in UK Homes – A Time Series Analysis And Modelling Approach

This paper presents an analysis of internal air temperatures measured hourly in the living rooms of 10 domestic buildings in the city of Leicester, UK. Time series analysis is used to develop empirical models of room temperatures in rooms that are neither mechanically heated nor cooled, during the summertime period of July and August 2009. The models are used in predicting future temperatures based on past measured values. Such models can enable overheating risk alerts for homeowners and public authorities to be more accurately estimated and targeted. 

Wind Assessment in Urban Area with CFD Tools – Application to Natural Ventilation Potential And Outdoor Pedestrian Comfort

The paper presents a numerical methodology to assess wind pedestrian comfort and natural ventilation in urban areas. UrbaWind, an automatic computational fluid dynamics code, is improved to model the wind in dense urban environments. The turbulence modelling, that is to say the dependence of turbulence length on the distance from wall, and the model constants are calibrated in order to reproduce precisely flow separation around buildings walls. Numerical results match well with the experiments: separation patterns, pressure field on walls, and wind speed in dense urban area.

Investigation of Thermal Comfort And Airflow in A Naturally Ventilated Lightweight House in A Bush Fire Prone Area

Building performance simulation has been utilised for the investigation of thermal comfort and airflow within a naturally ventilated, self-sufficient house in a bushfire prone area. Lightweight construction with Phase Change Materials (PCM) was proposed as an appropriate solution to respond to the brief. The simulations modelled the effects with and without PCM, to demonstrate the reduction in temperature swings throughout design days.

Concept 2226, A New High Performance Office Building Without Mechanical Heating,Cooling And Ventilation Devices

Nowadays building simulation tools have been proven to be very effective in the planning process of building projects to find optimal solutions for the buiding design. This paper has the goal to compare the simulation results and the measured data of the highly innovative office  building named "2226" in Austria. Extensive research work has been done by using thermal simulation and CFD simulation tools to optimise a novel high performance office building concept without mechanical devices for heating, cooling or ventilation.

Actual Situation of Ventilation Design And Evaluation using Contamination Area Ratio of Smoking Rooms

Contamination distributions were calculated and evaluated by contamination area ratio at respiration height for actual smoking rooms. As a result, 1) Dust contamination area ratio is about 20 % for required ventilation volume by Guidelines. 2) Ventilation volume based on smell level 1 is almost as much as that based on dust criterion. 3) Contamination area ratio of smell level is more rapidly reduced than that of dust as ventilation volume is increased.