The effect of CO2 on the nocturnal restlessness of an Alzheimer patient

At typical indoor CO2 levels there is no scientific evidence that CO2 is harmful to comfort and health of healthy persons, though there is a potential for negative effects on some aspects of performance. Research also indicates that insufficient bedroom ventilation may negatively affect the quality of sleep.

Energy performance of active polarization filters vs. conventional filters in HVAC systems

Pressure drop due to filters embedded in HVAC systems is one of the energy loss causes in building air conditioning systems, which can become important in large all-air systems with highly demanding filtering needs, such as hospitals, clean rooms, laboratories or pharmaceutical environments.

How the filtration of the incoming air decreases the particle concentration within a school equipped with a balanced ventilation system

To study the impact of the filtration efficiency level on the particle concentration in a rural school equipped with a balanced ventilation system with heat recovery, measurements of indoor and outdoor particle concentrations have been carried out by using three different efficiency filters. The tested filters are respectively classed G4, F7 and F9 according to NF EN 779 (2012).

Radon concentration control by ventilation, and energy efficiency improvement

Radon gas is a pathological agent confirmed by World Health Organization in terms of increasing the risk of lung cancer generation when it is inhaled by human in high concentration. This gas comes from soils with uranium content (i.e. granite terrain) and penetrates through the building envelope, such, as floors or basement walls. Its accumulation in indoor spaces increases the radon concentration level, constituting a health problem for occupants. This can be handled by rehabilitation actions in buildings that reduce indoor concentration to acceptable levels.

Influence of air quality performance requirements on the demand of energy

The aim of this paper is to show the effects of variable ventilation rates on the demand of energy and air quality in dwellings, and how airtightness and wind affect this relation. It is interesting to estimate the relation between the air ventilation rate and airtightness of dwellings which makes the dwelling to be under-pressure in order to avoid infiltrations.

Evaluation of Ventilation and IAQ Parameters Measured in Social Housing in Madrid

Within this paper, an evaluation of Indoor Air Quality in residential buildings, and the experience after a building retrofit is shown. One residential building in a Madrid social housing neighbourhood serves as case study and base for the monitoring. 

Ventilation and health – a review

People in industrialised countries spend about 90% of their time indoors. Hence, a good indoor climate is essential for health and well-being. Ventilation of buildings plays an important role concerning health aspects of the occupants and inadequate ventilation may cause health costs that may have been avoidable if ventilation would have been adequate. Additionally, good or bad ventilation has impacts on the quality of the building, e.g. in very tight buildings, the risk of mould and dampness is higher if air change is insufficient.

Implementation of multi-zone ventilation methodology in the Spanish energy performance certification tool

The purpose of this paper is to enhance the importance of ventilation regarding energy use and stablishing methods in order to obtain as much data as possible about the behavior patterns of ventilation and infiltration in buildings.

A Study on the Reduction Effect of Ventilation and Heating Load by Installing Air-based Solar System in the Detached Houses

Using solar heat energy has been paid attention to as effective natural energy use. In this study, we deal with air-based solar heat system, which is used for not only ventilation but heating and hot water supply by hot air.

3D Fluid dynamic analyses of open joint ventilated facades applying experimental Stereo-PIV techniques

Open joint ventilated façade (OJVF) is a passive constructive system widely used to ameliorate envelop of buildings, improving their energy efficiency. A laboratory model of a ventilated façade with horizontal and vertical open joints was used to study thermal and fluid-dynamic behaviour of this system. Experimental Stereo Particle Image Velocimetry (Stereo-PIV 2D-3C) was applied to study the fluid dynamic performance of this model. In addition, thermal analyses were performed applying infrared thermography and air temperature monitoring inside the ventilated cavity.

Pages