IEA EBC Annex 68 – Indoor Air Quality Design and Control in Low Energy Residential Buildings

The overall objective of the IEA EBC Annex 68 is to provide scientific basis usable for optimal and practically applicable design and control strategies for high Indoor Air Quality (IAQ) in residential buildings. Naturally, those strategies should ensure minimal possible energy use. The project aims to gather existing and provide new data on pollution sources in buildings, model the indoor hydrothermal conditions and air quality as well as thermal systems, and will look to ways to optimize the provision of ventilation and air-conditioning.

Development of a compact single room ventilation unit with heat recovery dedicated to tertiary building

In the frame of the European project called Bricker, a new prototype of single room ventilation with heat recovery has been developed. This new unit is supposed to be installed in class rooms of an educational institution. This paper deals with the development of the first prototype of this unit. An empirical model of such device is also proposed in order to be coupled with a building model. This aims at determining the seasonal performance of the device and thus the potential energy saving (compared to other technologies) resulting from its use.

Spread in energy use in buildings dependent on choice of heating and ventilation system

The energy use in buildings is dependent on the choices made during the design, construction and renovation. The causes for these differences are, among others, caused by the behavior of the occupant of the building and the choice of heating and ventilation system. The European scheme of Energy Performance Certificates (EPCs) aims at reducing the energy use in the built environment. It is most common to calculate (i.e. not measure) the energy use for the buildings which are affected by the scheme.

Primary energy used in centralized and decentralized ventilation systems measured in field tests in residential buildings

Ventilation systems can save heat energy by using heat recovery, but consume electrical energy to power the fans. In practice, the energy efficiency of those systems can be lower than expected, when compared to the nominal values provided by the manufacturer. In this paper, results of a comprehensive field tests with 20 centralized and 60 decentralized ventilation systems for residential buildings and the calculation of the primary energy savings of those devices are presented.

Ecodesign Directive for Ventilation Units

Ventilation technologies are the key aspects to reach the target of nearly zero energy buildings. From 1st January 2016 on ventilation units have to comply with minimal energy efficiency criteria according EU Regulation No 1253/2014 of 7 July 2014 implementing Directive 2009/125/EC of the European Parliament and of the Council. Furthermore, residential ventilation units will have an energy label according EU Regulation No 1254/2014 of 11 July.

Field application of enhanced displacement ventilation system in an office of a Zero Energy Building in the Tropics

Conventional Displacement Ventilation (DV) system has been installed in an office of a Zero Energy Building (ZEB). Enhanced DV (EDV) system, consisting of fans mounted to the chair, which has been demonstrated in laboratory and field environmental chamber studies earlier was implemented for the first time in a full-scale office environment to assess its effectiveness of improving the thermal sensation of the occupants. Objective measurements and subjective assessments were conducted in the office with 12 occupants over a period of 2 weeks.

Wind-induced pressure coefficients on buildings dedicated to air change rate assessment with CFD tool in complex urban areas

The paper presents a numerical methodology to assess the natural ventilation. UrbaWind is an automatic computational fluid dynamics code. It was developed to model the wind in urban environments. The turbulence modelling, namely the dependence of turbulence length on the distance from wall, and the model constants were calibrated in order to reproduce with good agreements flow separation around buildings walls and pressure coefficient field on façades. Numerical results match well with the experiments: separation patterns and pressure field on walls in dense urban areas.

Optimization of indoor air quality through controlled cross ventilation in the retrofitting of residential buildings

As an alternative to adopting active architectural systems (mechanical systems) and taking advantage of the resources provided by nature, natural ventilation contributes interesting solutions to control the thermal balance and the air quality, and it is applicable in a variety of climate zones. Natural ventilation also solves some of the more common problems of mechanical systems, such as the noise factor and installation and maintenance costs.

Model Home 2020 – full-year measurements of daylight, energy and indoor climate in five single-family houses occupied by typical families: what has been learned

This paper describes Post Occupancy Evaluation survey and physical measurements of five families living for one year or longer in five houses located in Germany, Austria, France and UK, all part of the Model Home 2020 project. The houses are built according to Active House principles and focus on high performance on indoor environmental quality, energy performance and environmental impact. The survey is carried out seasonally during the test year when the family lives in the house to capture seasonal variations. Physical measurements were made in all main rooms of the houses.

Influence of moving objects on ventilation plan for smoking room

Ventilation plan for smoking room must deal with pollutants since they affect the air quality of adjacent rooms. Although ventilation plan typically maintains a negative room pressure to remedy this problem, the transport of indoor air pollutants between rooms is affected by moving objects, such as human movement and door opening. The purposes of this study were to evaluate the effects of moving objects on the rate of transport of indoor air pollutants and to propose a method of controlling contamination for smoking room.

Pages