Dwelling houses operative energetical claims minimalization by using controlled ventilation systems.

A renovation of a dwelling stock in Slovak republic primary mission is a dwelling environment quality increase and dwelling houses essential operative energetical claims  decrease. Considerable means of an operative energetical claims decrease of these buildings is their airiness reduction, that leads to an infiltration air change under level of sanitariness needful. A heat consumption for ventilation optimalisation beside a collateral dwelling environment quality increase is possible to reach through a controlled ventilation systems applications.

Method of calculating the season heat requirements for ventilation purposes in residential buildings.

Heat requirements of ventilation systems are becoming a dominant factor to be considered in energy balances prepared for residential buildings. This results from a consistent improvement of thermal insulating power and better tightness of partitions, as well as from the standards that ventilation systems have to meet in relation to the quality of the indoor air. This factor despite variable volumes of the air exchanged with the external environment, is not always considered in most estimates of thermal power quantities.

Overview of practice in various countries.

             

"Leaky condos" are building envelope failures.

A cautionary tale of what happens when the entire construction and development system breaks down.

A comparison of passive stack ventilation and mechanical extract fans in reducing condensation problems in homes.

A study comparing the effectiveness (as reported by occupants) of passive stack ventilation (PSY) and mechanical extract fans (MEFs) was carried out during the winter of 1996. This involved a face-to-face survey of 437 homes in England. More than 50% of the homes in the study had MEFs, 14% had PSV and 8% had humidistat-controlled MEFs (HMEFs). About 25% of the homes had either a kitchen or a bathroom with no ventilation device and 16% had no ventilation device in the home.

A sound measuring method.

 Calibrating air flow measurement devices is a constant headache for users in the field. Peter Downing explains how sophisticated ultrasonics can overcome the problem.            

Performance of curtain walls for pre-heating air.

For state of the art buildings ventilation heat loss can exceed 50 percent of the total heat loss of the building. Balanced ventilation systems with heat recovery from the exhaust air lead to bjg costs for ducts. Alternatively, the incoming air of exhaust ventilation systems can be pre-heated by curtain wall facades. A newly developed simulation program for transient analysis of curtain wall systems is validated by measurements. Parameter studies for pre-heating air with curtain walls are presented. Location, orientation, construction, and geometry are considered.

Controlling sound transmission through concrete block walls.

This Update discusses the various factors that affect sound transmission through different types of concrete block walls, including single-leaf walls, double-leaf walls and walls with gypsum board attached. Knowledge of these factors will assist construction practitioners to design and build walls with high levels of acoustic performance economically.

Sound isolation and fire resistance of assemblies with fire stops.

This Update examines various fire-stopping techniques that meet the intent of the National Building Code of Canada (NBC) with respect to fire resistance and that do not adversely affect the sound isolation of the wall assembly. The information is derived from the results of an industry-sponsored consortium project led by the National Research Council's Institute for Research in Construction (IRC).      

Pages