Submitted by Maria.Kapsalaki on Mon, 12/15/2014 - 10:39
Context: The case study presented here was carried out to assist the designers in making a decision about the use of chilled ceiling panels coupled with an air handling unit in a data center with limited usable ceiling area. Project Description: A continually operational data control center, located on the sixth floor of a triangular-shaped building was used for this study. The building is located in Frankfurt, Germany. The tenants requested a constant 22°C operative temperature for the space while the outside air temperature is below 26°C.
Submitted by Maria.Kapsalaki on Mon, 12/15/2014 - 10:37
The present contribution aims at a typical example of a low-energy house to repeat the known facts in environmental assessment of buildings, emphasize the need to use transient calculations of energy demand not only to optimize building envelope and operation of buildings but also in the assessment of their life cycle. It also outlines a possible way of comparing the built and operational energy within the life cycle of buildings, as a contribution to the debate on the implementation of the second Energy Performance of Buildings Directive (EPBD II).
Submitted by Maria.Kapsalaki on Mon, 12/15/2014 - 10:36
In this paper, the energy management system that has been developed for the CANOPEA building is detailed. It is based on a virtual represen-tation of the building system including envelope, do-mestic appliances and technical appliances. The paper presents a core high level language to model build-ing systems and a projection mechanism to generate mixed integer linear programming problems used for the generation of energy management strategies. It has been applied to the generation of energy management strategies for the CANOPEA building system.
Submitted by Maria.Kapsalaki on Mon, 12/15/2014 - 10:35
Climate change and rising energy costs necessitate a shift in how buildings that efficiently provide comfort are envisioned. With initiatives now aiming at bringing energy simulation into the mainstream of environmental design, the applicability of state-of-the-art simulations in formally non-constrained creative production needs to be re-evaluated.
Submitted by Maria.Kapsalaki on Mon, 12/15/2014 - 10:33
In this paper, the thermal behaviour of a ventilated window is studied. The particularity of this system is the existence of an airflow passing between the glasses of a triple glazing. The aim is to preheat outdoor air entering the room both by heat loss recovery and by solar gains. To evaluate the thermal performances of the window, a 2D model simulating the heat and mass transfers within the airflow window has been developed, and validated from experimental results. The effects of several parameters on thermal performances are investigated, e.g.
Submitted by Maria.Kapsalaki on Mon, 12/15/2014 - 10:32
This paper examines the creation of a new simulation tool designed to integrate the results of energy consumption models into the carbon projections for large portfolios of buildings. This is accomplished through the creation of the Individual Building Worksheet (IBW), which was designed to integrate with calculators and projections derived from the CACP Carbon Calculator.
Submitted by Maria.Kapsalaki on Mon, 12/15/2014 - 10:31
Considerable progress has been made in the field of building simulation for combined heat, air and mass transfer processes occurring in the indoor environment, yet concerns persist over the reliability and suitability of moisture property data integrated into available tools and the approaches taken in modelling physical phenomena. Particular interest lies in predicting the impact of indoor moisture production schemes and sources observed in housing, linked to occupant activity.
Submitted by Maria.Kapsalaki on Mon, 12/15/2014 - 10:09
The aim of this paper is to develop a new concept of sketch tools for the very steps of the design process. The originality lies in the use of optimization to define a global design of the building, the energy system and the control strategy. Therefore, an adapted model of the building has been realized, not directly using fine dynamic models (like those that can be found in tools TRNSYS, DOE2.2 and EnergyPlus...), but more coarse equations adapted to the sketch design phase. Those models are based on static and macroscopic equations investigating energetic and financial balances.